19
Tilt window sash mounting / top hung window frame mounting
tilt window frame mounting
To determine the installation variant depending on the sash height, refer to the following table or the
charts in section 3:
Min. sash high
Installation method
stroke
100 mm
stroke
200 mm
stroke
300 mm
stroke
400 mm
tilt window frame mounting
250 mm
600 mm
1100 mm
1500 mm
Tilt window sash mounting
200 mm
400 mm
650 mm
900 mm
top hung window frame mounting
150 mm
250 mm
350 mm
450 mm
⇐
Note!
Smaller sash heights
Please contact us if smaller sash heights are required.
20
2.2
Preparing to install
Danger!
Caution!
Incorrect use may cause injury to people and damage to property
Refer to the type label of the motor and the technical data in section "2.1" to
ensure that you have the correct motor for your installation situation.
9
Examine the delivered equipment immediately upon receipt and check it for transport damage.
Do not install the motor if it is damaged.
⇐
Note!
With tilt sashes, the clearance between frame and sash profile
must be at least 1 mm in order to provide for safe closing of the
window. If frame and sash profiles are flush, or if the sash profile
stands back from the frame profile on the interior side, it is nec-
essary to underlay the tilt sash bracket accordingly.
2.3
Calculation of force to open and close
⇐
Note!
With the formulae indicated below it is possible to determine the approximate force required to
open or close a (smooth-running) window;
Possible snow loads are to be considered.
⇐
Note!
The application formula considers tilt and top hung windows only. The maximum rated drive
force is to be taken from the technical data you will find in section „2“. If the values you calcu-
lated exceed the max. allowed force, please contact Gretsch-Unitas GmbH Baubeschläge.