PROGRAMMING INSTRUCTIONS 

 

 

Blocking or Adding a Time Limit to Certain Types of Calls 

 

This section covers how to restrict certain types of calls or add a time limit and/or keypad restriction to 

certain types of calls.  Before you begin programming, locate the Rate Band (4-digit code) that 

represents the type of call you are programming for, (see the Call Type Band Description Table below.)   

 

1. Make sure the phone is in the program mode. 

 

2a. If blocking a certain call type, enter the 4-digit rate band and press the * key.  Listen for one 

confirmation beep. 

6xxx *

   

  Example: 6082*

   

this example would block 411 or 1411 information calls

 

 

2b. If placing a time limit and/or restricting use of the keypad, enter the following information in this 
order for the call being programmed: 

4-digit Rate Band

(see Call Type Description Table for list of Rate Bands)

 

8 Zero’s must be entered next 
3-digit Time Limit 

(ex. 3 min. = 003, 15 min. = 015; to set the call back to unlimited, enter 255) 

01 must be entered next 
4-digit Keypad Allowance

(if the keypad is allowed during the call, enter 0008; if the keypad is not 

allowed during the call, enter 0001) 

Press the * (star) key to complete the entry; listen for one confirmation beep. 

 

    

6xxx     0000       0000        xxx         01       0008 

  *   

 

                 

×

                

×

                         

×

                       

×

                      

×

                     

×

                         

×

  

     Call Type    Default       Default                          Default     Keypad

     

Completes 

                      

    Rate Band

    

Setting       Setting     Time Limit    Setting   Allowance      Entry 

 

Example: 6000 0000 0000 015 01 0008 *  

this example would set a 15 minute time limit with 

unlimited keypad use for 7-digit calls.   

 
 

Call Type Band Description Table 

 

This table shows the 4-digit rate band for each call type and its factory setting. The factory setting may 

vary depending on what was requested at the time of order. *Definitions of local, toll & long distance 

calls may vary depending on your region.  Some regions have the same dialing pattern for local and long 

distance calls and phones in those regions may require a rate file to be downloaded if the calls must be 

treated differently 

(fees may apply).

  If you have any questions, please contact G-TEL Technical Support.

 

 

Call Type

 

 

 

 

 

 

Factory Setting

 

      

Rate Band 

 

 

7-digit 

Local* 

Calls 

    Unrestricted 

  6000 

  

10-digit 

Local* 

Calls 

    Unrestricted 

  6001 

1+ 

10-digit 

Toll/Long 

Distance* 

calls 

  Blocked   6098 

 

411 

1411 

Information 

Calls 

   Blocked   6082 

  

Incoming 

Calls 

     Unrestricted 

  6088 

  

1+ 

555-1212 

Information 

Calls 

  Blocked   6101 

  

1+ Area Code + 555-1212 Information Calls  

Blocked 

 

 

6102   

 

1-800 

Toll 

Free 

Calls 

    Unrestricted 

  6104

 

1-888, 1-877, 1-866, & 1-855 Toll Free Calls  

Unrestricted   

 

6079 

Содержание 2150 Smart Bell Style

Страница 1: ...Includes Instructions on Installation Programming Troubleshooting ...

Страница 2: ...2 ...

Страница 3: ...THE TELEPHONE LINE 7 RE CONNECTING THE UPPER LOWER HOUSING 7 PROGRAMMING INSTRUCTIONS 8 ENTERING THE PROGRAMMING MODE 8 BLOCKING OR LIMITING CERTAIN TYPES OF CALLS 9 RATE BAND DESCRIPTION TABLE 9 CHANGING THE RECEIVER VOLUME 10 UN BLOCK OR UN RESTRICT A CERTAIN CALL TYPE 10 PROGRAMMING FOR A PBX SYSTEM 10 TROUBLESHOOTING REFERENCE 11 PROBLEM NO DIAL TONE 11 PROBLEM NO DISCONNECT AFTER HANGING UP 1...

Страница 4: ... that you read the portion of the manual related to your support needs so that a technician will be able to better assist you G TEL Technical Support via e mail support payphone com G TEL Technical Support via phone 1 800 884 4835 Technical Specifications Telephone line powered 42 VDC to 56 VDC Loop current range 22 mA to 90 mA B 1 POTS line loop start standard dial tone 600 120 Hz Repair Departme...

Страница 5: ...lternative to Toggle Bolts 1 Ensure that the wall that the backboard or enclosure is to install to is flat level 2 The top height of the backboard or enclosure should be determined by the following Standard Height 58 from floor Wheelchair Accessible 51 from floor 3 Place the backboard or enclosure against the wall at the desired height mark the Line Wire Entrance Hole Mounting Holes to be used the...

Страница 6: ...Lower Housing to the Mounting Device 1 Fasten two security studs to the rear of the lower housing If the mounting device you are installing to does not provide security stud holes do not fasten security studs to rear of lower housing 2 Insert the telephone line cable through the line wire entrance hole 3 Hold the lower housing against the mounting device and insert the security studs into the secu...

Страница 7: ...nnect the telephone line with the payphone Telephone Communication cable usually consists of 2 or more pairs of color coded wire 2 Connect one pair of communication cable wire to the two points of the Telco interface box D Marc location that the telephone line originates from 3 Connect the opposite end of the same pair of wire to the top left right terminal screws terminal block is located on the ...

Страница 8: ...e beeps then re try the entry All program entries can be done in one session in no specific order 1 Open the upper housing of the payphone see Separating the Upper Lower Housing on page 6 2 Ensure that the dial hookswitch connector JF the Ni Cad battery JD are both connected 3 Push hold the black program button PB1 on the circuit board 4 Take the handset off hook while program button is held down ...

Страница 9: ...ess the star key to complete the entry listen for one confirmation beep 6xxx 0000 0000 xxx 01 0008 Call Type Default Default Default Keypad Completes Rate Band Setting Setting Time Limit Setting Allowance Entry Example 6000 0000 0000 015 01 0008 this example would set a 15 minute time limit with unlimited keypad use for 7 digit calls Call Type Band Description Table This table shows the 4 digit ra...

Страница 10: ...pg 9 3 Enter 0000 0000 255 01 0008 4 Press the star key to complete the entry listen for one confirmation beep Programming an Access Code for PBX Phone Systems The following procedure shows the steps necessary to allow the Smart Coinless Bell Phone to work on a PBX phone system The phone will automatically dial the PBX access code before the users destination number 1 Make sure the phone is in the...

Страница 11: ...e Cause 3 Hook switch contacts are shorted Solution Disconnect one hookswitch wire Test hookswitch with a multi meter by setting the meter to ohms placing one lead of the meter on the disconnected hookswitch wire the other lead on the connected hookswitch wire When hookswitch lever goes on off hook the meter should show signs of resistance If the meter reads the same when hookswitch lever goes on ...

Отзывы: