3
Xenon lamp operation illustration
•
Search light have the power from 2KW-7KW. Light upon power.
•
Pay more attention to the sign of “+” and on the lamp. The big size screw and
with the piece are “+”. The small is “-” . The lamp must connect right with the
power otherwise the lamp will burn
•
Do not touch the lamp case by hand. Use cotton which be dipped in the
alcohol to wash the lamp case to avoid the lamp case be dirty by the hand-
wed. Oil or dusty before use the lamp. The dirty will have the influence to the
light rate and lift-span.
•
Set the - end of the lamp at the lamp shelf safety. Put the + end on the bracket
.Do not try to just set on one end. Any pressure or torsion should not put on
the xenon lamp.
•
Put on power under the situation that the DC power impulse less than
3.5%otherwise will short the life of the lamp
•
The current of xenon lamp has a limit otherwise will short the life of the lamp
and even explode .It will be better for the life span of the lamp if you just use
the 70-80% permitted current at the beginning.
•
The interface of lamp and lead line must smooth and connect well. Must check
the connect condition to avoid the resistance time.
•
Xenon lamp which higher than 2000w uses disassembly connect line. Must
use two spanners while install lamp. One holds the copper gap. Another turns
the hexangular screw. Any pressure or torsion not permitted.
•
Xenon ball lamp is super-high voltage discharge lamp. It must out of hit
because there has high-voltage before work and working in it. when the lamp
working it must be equipped in well cool case to avoid the case of lamp break
or the strong ultraviolet radiation burn skin or eyes
Usage and maintain
Search light is an effective special light. About this using method and maintain has a
special inquiry, in order to use the lamp in the right way, please attention to the
following:
In case of safety, please switch off the power before install or replace the lamp. And
then open the front cover of the lamp. But please do not make mistake with the anode
and cathode of the lamp. The thin and tine side is cathode and smooth side is anode.
Swing the anode side in the metal ring hole in front of the lamp and connect with the
copper packet hand and screw the cap. Set the cathode side in the copper lamp
holder hole at the copper center hole on the white post which at the end of the light.