51839360X18NXS_V_1_1.DOC
25/49
213-234
Circle 3
235-255
Circle 2
Control channel 3 - Shutter, Strobe
DMX-value
Feature
0
Shutter closed
1-139
Shutter opening
140-149
Reset (after 3 seconds)
150-219
Strobe-effect with increasing speed
220-229
No function (shutter open)
230-239
Random strobe-effect
240-255
Shutter open
Control channel 4 - Dimmer
DMX-value Feature
0
Dimmer closed
1-128
Dimmer Spot from 0 to 100 %
129-186
Dimmer Spot from 100 to 0 %
187-194
Dimmer closed
195-255
Dimmer Wash from 0 to 100 %
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) Mechanically moved parts like axles, eyes and others must not show any traces of wearing (e.g. material
abrading or damages) and must not rotate with unbalances.
4) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The lens has to be replaced when it is obviously damaged,
so that its function is impaired, e. g. due to cracks or deep scratches!
CAUTION!
The objective lens will require weekly cleaning as smoke-fluid tends to building up residues, reducing the
light-output very quickly. The cooling-fans should be cleaned monthly.
The gobos may be cleaned with a soft brush. The interior of the fixture should be cleaned at least annually