Future Automation SPS 1200 Скачать руководство пользователя страница 2

Introduction: 

Safety Information

Page 1 of 22 // email [email protected]  tel: +44 (0) 1438 833577  fax: +44 (0) 1438 833565

SPS 800 / 1200 - Sliding Panel System Plasma Advance

Warnings:
1.

Read all technical instructions fully before installation and use. It is the installer’s responsibility to ensure that all 
documentation is passed on the end user and read fully before operation.

2.

Keep all documentation.

3.

Heed all warnings.

4.

Follow all technical specifications and instructions during installation.

5.

Do not use near water unless the product has been specifically designed to do so.

6.

Clean only with a dry cloth.

7.

Do not defeat the purpose of the polarized or grounding type plug. A polarized plug has two blades, one wider 
than the other. A grounding type plug has two blades and a grounding prong. The wide blade or third prong are 
provided for your safety. If the provided plug does not fit your outlet, consult an electrician or contact the 
manufacturer.

8.

Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the 
point where the exit from the apparatus.

9.

Unplug the apparatus during lightning storms or when unused for long periods of time.

10.

Only use attachments/accessories specified by the manufacturer.

11.

Refer all servicing to qualified personnel. Servicing is required regularly on an annual basis, when the apparatus is 
damaged in any way, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been 
exposed to rain or moisture, does not operate normally, or has been dropped.

12.

To completely disconnect the apparatus form the AC mains, disconnect the power cord plug from the AC 
receptacle on the power control box.

13.

To prevent overheating, do not cover the apparatus. Install in accordance with the instructions.

14.

UK, Ireland and Hong Kong only – The power cord is supplied with a 13A plug having an earthing pin. The 
apparatus is earthed and this pin is not required for safety, merely to operate the safety shutter of mains outlet.

15.

No naked flames such as lit candles should be placed on the unit.

16.

Observe and follow the local regulations when disposing of batteries.

17.

Do not expose the unit to dripping or splashing fluids.

18.

Do not place objects filled with liquid, such as vases, on the unit.

19.

Do not expose the batteries to excessive heat such as sunshine, fire or the like.

20.

For all mounted apparatus, the apparatus should be installed on solid wood, bricks, concrete or solid wood 
columns and battens.

21.

Always turn off power at source before putting on or taking off parts and cleaning.

22.

Do not use outdoors unless marked for outdoor use.

23.

Exceeding the weight capacity can result in serious personal injury or damage to equipment.

Future Sound & Vision trading as Future Automation intend to make this and all documentation as accurate as possible. However, Future
Automation makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every
possible contingency in connection with the installation or use of this product. The information contained in this document is subject to
change without prior notice or obligation of any kind. Future Automation makes no representation of warranty, expressed or implied, 
regarding the information contained herein. Future Automation assumes no responsibility for accuracy, completeness or sufficiency of the
information contained in this document.

Safety Disclaimer

Important Safety Instructions
Explanation of graphical symbols
-(Electric Shock Symbol) = The lightning flash within an equilateral triangle is intended to alert you to the presence of un-insulated 
“dangerous voltage” within the products enclosure that may be of sufficient magnitude to constitute an electric shock to persons
-(Caution Symbol) = The exclamation point within an equilateral triangle is intended to alert you to the presence of important 
operating and maintenance (servicing) instructions in the literature accompanying the product
-(Tools Symbols) = The tools symbol within a coloured square are intended to highlight the required tools necessary for correct and 
safe installation of the product. These are intended as a 
guide only, and it is at the installer’s discretion as to which tools are used.

WARNING:

RISK OF ELECTRIC SHOCK, ONLY AUTHORIZED INSTALLERS TO OPEN THE POWER CONTROL BOX.

WARNING:

To reduce the risk of fire or electric shock, do not expose electrical parts to rain or moisture, unless the 

product has been specifically designed to do so.

WARNING:

Failure to provide adequate structural strengthening, prior to installation can result in serious personal injury or damage to the

equipment. It is the installer’s responsibility to ensure the structure to which the component is affixed can support the four times the
weight of the component.

WARNING:

Do not exceed the weight capacity. This can result in serious personal injury or damage to the equipment. It is the installer’s

responsibility to ensure that the total combined weight of all attached components does not exceed that of the maximum figure stated.

WARNING:

Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equip-

ment! It is the installer’s responsibility to make sure the structure to which this component is attached can support five times the combined
weight of all equipment. Reinforce the structure as required before installing the component.

Caution 

Warning

Beware of 

Moving Parts

Keep Hands 

Clear

Danger 

Electricity

Содержание SPS 1200

Страница 1: ...1438 833565 ISSUE 008 InstallationInstructions SPS800 1200 SlidingPanelSystem PlasmaAdvance Design Highlights Range of Single Panel and Split Panel Options Space Efficient Design Wide Range of Cabinet...

Страница 2: ...acity can result in serious personal injury or damage to equipment Future Sound Vision trading as Future Automation intend to make this and all documentation as accurate as possible However Future Aut...

Страница 3: ...hecks 5 Stage 2 Before you Begin 2 6 Electrical Connections 6 Stage 3 Mark the Screen Position in the Enclosure 7 Stage 4 Positioning the Moving Panel Mechanism 8 Stage 5 Fitting the Moving Panel Mech...

Страница 4: ...ct your statutory consumer rights The following is excluded from warranty service Malfunctioning caused by misuse or damage accidental or otherwise or service modification by persons not authorised by...

Страница 5: ...for your screen Your pack may also contain a custom adapter if your screen is not VESA compatible Parts not to scale Package Contents 1 Panel Mechanism Right 2 Panel Mechanism Left 3 Drive Unit 4 Plas...

Страница 6: ...hem Plug the units together with the leads from the control box The panel mechanism connection can be found tucked in one end of one of the mechanisms See sheet 3 for further details of the electrical...

Страница 7: ...y function Installation Stage 2 Page 6 of 22 email info futureautomation co uk tel 44 0 1438 833577 fax 44 0 1438 833565 SPS800 1200 SlidingPanelSystemPlasmaAdvance It is VERY important that when all...

Страница 8: ...nclosure Firstly mark where you intend the top of the plasma screen to be on the back wall of the enclosure Then mark a line showing where the centre of the screen opening will be It may be helpful to...

Страница 9: ...ey need to be Make sure that you have the mechanisms in the down and in position at this point Place one of the moving panel mechanisms on the side of the enclosure Raise the mechanism until the mount...

Страница 10: ...ck of wood knowing they are both at the correct height alternatively 2 screws can be used Fitting The Moving Panel Mechanism The moving panel mechanisms should be positioned roughly 4mm in from the ed...

Страница 11: ...ith nuts through both these joints both ends From the pre test earlier you should be able to make sure the shafts are not 180 degrees out of sync at this stage The drive unit is a telescopic piece of...

Страница 12: ...k of the Screen Image shows where to measure From this measurement it is possible to determine where to drill the holes in the wall Measure the distance from the top of the screen down to the centres...

Страница 13: ...t that you took in the previous stage You can also mark where the sides of the wall plate need to be The holes are 170mm apart so mark two vertical lines 85mm to each side of the centre line you marke...

Страница 14: ...of the Plasma Advance Unit can slide up and down the channels Firstly operate the Plasma Advance Unit so that it is in the OUT position This should make it easier to determine where the mechanism need...

Страница 15: ...To connect the three mechanisms together electrically is very simple Each mechanism has a set of wires coming from it On the ends of the wires are control box inserts and block connectors These wires...

Страница 16: ...Plates Following fitting the mounting plates it is a good time to set the mechanism is still operating correctly Use the supplied IR remote to control the mechanism The mounting plates fix to the runn...

Страница 17: ...dvance BACK PANEL Mounting Plate Height 5mm Clearance Mounting Plate Height Fix the front panel to the enclosure Measure the height of the panel mounting plates from the bottom of the opening Remove t...

Страница 18: ...ote control and wait for the Plasma Advance mechanism to reach its pre set out position Once out press B on the remote control repeatedly to pulse the mechanism out until the frame is extended fully T...

Страница 19: ...ndicators 568A 568B 1 12V SUPPLY 12V SUPPLY CURRENT LIMITED W G W O 2 12V LATCH When 12V attached device will go OUT When 12V removed device will go IN G O 3 GROUND GROUND W O W G 4 PIN 4 NOT USED BL...

Страница 20: ...se an RJ25 connector in the socket marked RS232 on the control box to operate using RS232 Details Baud rate 9600 Stop bit 1 Parity None Databits 8 Pin 1 RX Pin 6 TX Pin 3 4 GROUND Pin 2 TX Pin 3 RX Pi...