background image

In

st

all

at

io

n

IR

 C

on

tro

l

AL965 Actuator Lift

IR Controls

General Wiring

IMPORTANT
If the mechanism is left without
power for more than 14 days, all
memory positions will be lost. If
this is the case, the mechanism
will need to be reset, see page 6
for further information.

Future Automation IR Remote

Controller needs x2 AAA batteries
which are provided within the
packaging

Replacing batteries

Out

- Raises

the screen to
stored position

In

- Lowers

the screen to
stored position

Stop

- Will stop

the operation at
any point

In manual 
override

Out manual 
override

Store

- Stores the

current location into
the AL965 memory

Page 14 of 18 // email [email protected]  tel: +44 (0) 1438 833577  fax: +44 (0) 1438 833565

Storing Positions

Use the manual buttons on the
controller to raise and lower the
screen to the desired positions.
Once the screen is in the 
lowered position press STORE
then press IN to store the current
location. Use the manual buttons
to raise the screen to the desired
height, press STORE then press
OUT to store the OUT
position. 
The IN and OUT buttons will then
raise and lower the screen to the
stored locations automatically.

Safety Note

When the mechanism is moving, if any button
is pressed apart from those already assigned,
the mechanism will stop immediately.

Power Supply

Control Box

IR Sensor

Motors

AC Mains Power 

Содержание AL965

Страница 1: ...0 1438 833565 ISSUE 008 InstallationInstructions AL965ActuatorLift Design Highlights Push up lid Full cable management Compact design for minimum spatial requirements Only 20mm of height above televis...

Страница 2: ...ult in serious personal injury or damage to equipment Future Sound Vision trading as Future Automation intend to make this and all documentation as accurate as possible However Future Automation makes...

Страница 3: ...u Start 5 Resetting The AL965 5 Stage 2 Fixings To The Cabinet 6 Stage 3 Releasing The Screen Uprights 7 Stage 4 Aligning The Screen 8 Stage 5 Mounting The Screen 9 Stage 6 Inserting The Shelf 10 Stag...

Страница 4: ...use or damage accidental or otherwise or service modification by persons not authorised by Future Automation or the use of any non Future Automation supplied parts Any electrical or other environmenta...

Страница 5: ...reen Uprights 1 10 Top Bracket 1 11 Push Bar 1 12 Cable Management 2 Power Supply Unit 3 RF Control Box 4 RF Manual Key Pad 5 Remote Control 6 IR Control Box 7 IR Remote Control Not Shown On Page 8 x2...

Страница 6: ...BUTTON shown until the mechanism is fully lowered Release then hold down again for 5 seconds AL965 mechanism should make a small down then up movement to show the reset The product is then ready to us...

Страница 7: ...mechanism into the cabinet and fix into place fixings not supplied Check the measurements of the cabinet to the technical sheet x10 optional fixing holes in base plate Fixing holes Page 6 of 18 email...

Страница 8: ...44 0 1438 833577 fax 44 0 1438 833565 AL965ActuatorLift Loosen upright bolts as shown to release screen uprights from the screen plate Remove screen up rights by unhooking over the horizontal bars Re...

Страница 9: ...ly down the screen needs to be just under the top lid Mounting holes for adjusting the screen plate height To change the height of the screen plate loosen the 4 nuts so the locking strip can run freel...

Страница 10: ...washers provided Once the screen uprights are attached overlap the screen over the horizontal bars the same way as they were taken off Tighten x4 bolts back up to lock the screen into position as show...

Страница 11: ...fixing holes x15 Fixing holes x15 To adjust the height of the shelf loosen the grub screws in the fixing posts x4 move the shelf up or down to the desired height then tighten the grub screws back up...

Страница 12: ...felt pad onto the underside of the lid so it s in line with the push bar Make sure that when the mechanism opens the push bar is in contact with the felt pad at all times Loosen the 2 screws shown abo...

Страница 13: ...n runs along the felt pad The mechanism movement should look like this Make sure that the lid doesn t fall back over its self when the unit opens Product is level and square in the cabinet The mechani...

Страница 14: ...USED W G W O 2 12V LATCH PIN 2 NOT USED G O 3 GROUND GROUND W O W G 4 DEVICE LATCH Short to GROUND pin 3 device will go OUT remove short device will go IN BL BL 5 PIN 5 NOT USED W BL W BL N A 6 DEVIC...

Страница 15: ...res the current location into the AL965 memory Page 14 of 18 email info futureautomation co uk tel 44 0 1438 833577 fax 44 0 1438 833565 Storing Positions Use the manual buttons on the controller to r...

Страница 16: ...ess and hold to raise the screen Press and hold to lower the screen When presetting and storing the heights you need to use the manual keypad In Closed position Out Open position Manual Keypad Use to...

Страница 17: ...ontact your installer Symptom Cause Remedy Page Power removed for long periods Perform system reset 5 or 14 IR receiver not plugged in Connect IR receiver into IR IN on interface 15 Remote control or...

Страница 18: ...Distance 950mm 37 4 Max Television Size W H 1750x965mm 68 9x38 Control IR Remote RF Remote Contact Closure Power Supply 240V or 110V Control Of 3rd Party Product No Output Power Supply No DC Motor Su...

Страница 19: ...Technical overview Page 18 of 18 email info futureautomation co uk tel 44 0 1438 833577 fax 44 0 1438 833565 AL965ActuatorLift Notes...

Страница 20: ...e Automation Unit 2 Kimpton Enterprise Park Claggy Road Kimpton Hertfordshire SG4 8HP United Kingdom Tel 44 0 1438 833 577 Fax 44 0 1438 833 565 Email info futureautomation co uk www futureautomation...