26
Automatic Control
APPENDIX H
Internal Switches Reference Page
The main circuit board inside the control box has two additional 4-way dip switches.
Switch 101 functions are described below.
Switch 100 is used for auxiliary valve confi gurations and other test simulations.
Manual Raise/Lower
Override in Auto OFF
Manual Raise/Lower
Override in Auto ON
1
False Strike
Rejection Disabled
False Strike
Rejection Enabled
2
Manual R/L Ramp OFF
Manual R/L Ramp ON
3
Test Mode
Operating Mode
4
SW100
(Factory Settings)
SW101
(Factory Settings)
Default ON position allows the manual raise
switch to send the raise signal to the valve
even when in the automatic mode.
Default ON position fi lters out signals that are
out of time with laser, strike multiple channels
at the same time (strobes), or are at an unreal-
istic vertical distance from the previous strike.
Default ON position allows a progressive
increase for the valve to get to the 100% open
state in the fi rst second.