Ver.1.0
41
RON (
RF circuit ON
)
[Format]
RON
[Response]
P0: Normal
end
N0: Command
error
[Function]
- This command turns on the RF circuit. If the RF circuit has been already turned on, N0 response is
returned after executing this command.
[Example of use]
>@RON<Cr><Lf>:
Turn on the RF circuit.
<P0<Cr><Lf> :
Normal end.
SPD (
Show/set data transfer mode
)
[Format]
SPD(: Data transfer mode)
Data transfer mode: 1 or 2
[Response]
x:
Current setting value
P0: Normal
end
N0: Command
error
[Function]
-
This command show and/set data transfer mode.
-
The data transfer mode is “Interchange” mode if the setting value is “1”.
-
The data transfer mode is “Communication Distance Extend” mode if the setting value is “2”.
-
Setting of the data transfer mode by this command is temporary. If the FDP03 is reset by RST
command or initialized, the mode is returned to the setting of the bit 5 of the REG10.
x (Setting Value)
Data Transfer Mode
1 Interchange
Mode
2
Communication Distance Extend Mode
[Example of use]
>@SPD<Cr><Lf>:
Show the data transfer mode.
<1<Cr><Lf> :
The mode is “Interchange” mode.
>@SPD2<Cr><Lf>:
Set the data transfer mode to “Communication Distance Extend” mode.
<P0<Cr><Lf> :
Normal end.
The data transfer mode should be same setting among communication
partners. If the mode is different each other, it is impossible to
communicate with.