Ver.1.0
38
POF (
Release low power stand-by mode
)
[Format]
POF
[Response]
P0: Normal
end
N0: Command
error
[Function]
- The operation mode is returned from “Low power stand-by mode” to “Normal operation mode” by this
command.
[Example of use]
>@POF<Cr><Lf>:
Release low power stand-by mode.
<P0<Cr>Lf>:
Normal end.
N0 response is returned if this command is executed during normal
operation mode.
PON (
Set low power stand-by mode
)
[Format]
PON
[Response]
P0: Normal
end
N0: Command
error
[Function]
- The operation mode is set to “Low power stand-by mode..
[Example of use]
>@PON<Cr><Lf>:
Set low power stand-by mode.
<P0<Cr>Lf>:
Normal end.
N0 response is returned if this command is executed during low power
stand-by mode.