2. WIRING
2-6
2.2.4
Connection of Terflex
®
linear sensor
When connecting the Teleflex
®
linear sensor AR4102/AR4302 instead of the FAP-6111, do
the following modification.
1. Cut the black jumper at the back of the AR4102/4302.
DO NOT
cut the red jumper.
2. Make the cable connection as shown below.
3. Change the position of jumper switch JP-2 from #3-4 to #1-2, referring to the illustration
shown on page 2-4.
4. Set SELECT RRU to “LINEAR SENSOR” on the DOCKSIDE SETUP menu. For further
details, see chapter 3.
1
2
3
4
5
SPU Board
(64P1140)
TB13
Linear sensor
AR4102
or
AR4302
RED
WHT
BLK
BARE
Processor unit
Connection of linear sensor AR4102/AR4302