3. ADJUSTMENTS
3-4
4. Select [4 Hull Unit Setting].
5. Select [1 REG TD Position].
The following confirmation message appears.
Note:
When the transducer position is already registered, the following message
appears. To re-register the transducer position, select [Next] the left click.
6. Confirm that transducer is retracted, then select [Next].
7. Confirm that the transducer can be protruded fully, then select [Next].
8. Check the safety and press the
(Full-protrude) key to protrude the transducer.
9. When the transducer is at full protrusion, select [Next].
10. Press the
(Retract) key to retract the transducer.
11. Select [Quit].
Note:
If transducer registration is aborted for any reason, the following message ap-
pears. Select [Quit] to close the message and restart the procedure once safety is en-
sured.
Menu
Quit
Installation Setting
Hull Unit Setting
1 REG TD Position
: Fixed Position
2 Middle Key Setting
3 Heading Adjust1
4 Heading Adjust2
5 Hull Unit Stroke
: 0.0°
: 0.0°
: 800mm
TD Position Registering 1/4
Register the transducer position?
To register the position now, fully retract the transducer
then left click [Next]. To register the position at a later
time, left click [Cancel].
Next
Cancel
TD Position Re-registration Confirmation
Transducer positions are already registered.
Are you sure you want to re-register positions?
Left click [Next] to re-register positions, left click [Cancel]
to keep the currently registered positions.
Next
Cancel
TD position Registering 2/4
To register this position, full protrusion is required.
Is safety ensured and full protrusion possible?
Left click [Next] if safety is ensured and full protrusion is
possible, otherwise, left click [Cancel].
Next
Cancel
TD position Registering 3/4
Next
Cancel
Check safety first, then press the ↓ key.
After the transducer is fully protruded, left click [Next].
To register the position at a later time, left click [Cancel].
TD position Registering 4/4
Quit
Press the ↑ key to retract the transducer.
When the transducer is fully retracted, left click [Quit] to complete the
registration.
Registering Transducer Positions
Ensure safety before registering transducer positions.
Quit
Содержание FSV-75
Страница 50: ...1 MOUNTING 1 42 This page is intentionally left blank ...
Страница 118: ...D 1 6 Mar 2019 H MAKI ...
Страница 119: ...D 2 22 Aug 2018 H MAKI ...
Страница 120: ...D 3 22 Aug 2018 H MAKI ...
Страница 121: ...D 4 5 Dec 2018 H MAKI ...
Страница 122: ...D 5 5 Dec 2018 H MAKI ...
Страница 123: ...D 6 16 Apr 2019 H MAKi ...
Страница 124: ...D 7 16 Apr 2019 H MAKI ...
Страница 125: ...D 8 16 Apr 2019 H MAKI ...
Страница 126: ...D 9 16 Apr 2019 H MAKI ...
Страница 127: ...D 10 9 Oct 2018 H MAKI ...
Страница 128: ...D 11 22 Apr 2019 H MAKI ...
Страница 129: ...D 12 9 Oct 2018 H MAKI ...
Страница 130: ...D 13 9 Oct 2018 H MAKI ...
Страница 131: ...D 14 6 Mar 2019 H MAKI ...
Страница 132: ...D 15 19 Nov 2018 H MAKI ...
Страница 133: ...D 16 8 Jan 2019 H MAKI ...