2.12 Track Test (Simulation Display)
Do this test when the radar is not being used.
The simulation display tests the ATA processor for proper operation. The figure below shows
the starting picture of the simulation display. Each mark moves as time passes. Check that
each target’s data is reasonable.
1. Press [MENU], [7], [7], [0], [0], [4], [4].
2. Press the [ENTER/SELECT] key to start the test.
3. It takes approximately three minutes for all vectors to be displayed completely on the
screen. The simulation display does not need radar, gyrocompass nor speed log input;
seven targets on various courses and speeds are provided.
Target Course Speed
CPA
TCPA
(kt)
(nm)
(min)
Target A
90.0°T
10.0
1.0
10.4
Target B
0.0°T
0.0
4.0
-
Target C
180.0°T
10.0
1.7
28.2
Target D
216.5°T
23.8
0.9
15.0
Target E
273.5°T
14.2
6.0
22.5
Target F
180.0°T
20.0
0.0
30.0
Target G
24.6°T
15.6
4.0
43.6
4. The simulation continues for five minutes and then repeats. To quit the test sequence,
repeat step 1.
2.13 Outputting Target Data
Target data may be output to external equipment as follows:
1. Press [MENU], [7], [7], [0], [0].
2. Press the [6] key to select OFF, REL, TRUE from the TTM field as appropriate.
1. Press the [ENTER/SELECT] key followed by the [MENU] key.
A
F
E
D
B
C
G
XX
000 010
020
030
040
050
060
070
080
090
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
260
270
280
290
300
310
320
330
340
350
Содержание FR-1500 MARK-3
Страница 1: ...15 MULTI COLOR HIGH PERFORMANCE SHIPBORNE RADAR AND ARPA FR 1500 MARK 3 SERIES Back ...
Страница 13: ...xi CONFIGURATION OF FR 1500 MARK 3 SERIES RADARS VIDEO PLOTTER RP 17 or RP 180 ...
Страница 14: ...xii This page is intentionally left blank ...
Страница 62: ...This page is intentionally left blank ...
Страница 86: ...This page is intentionally left blank ...
Страница 118: ... 9 6 FR 1500 MARK 3 series interfacing diagram CHANNEL 2 OUTPUT TTM ...
Страница 119: ... 9 7 ...
Страница 123: ......
Страница 124: ......
Страница 125: ......