-1.10-
1.12 Selecting the Range Scale
The display range scale is changed by pressing the [+] and [-] keys. The selected range scale and
range ring interval are shown at the upper left corner on the screen. When a target of interest
comes closer, reduce the range scale so that it appears in 50-90% of the display radius. The range
scales are 0.125-0.25-0.5-0.75-1.5-3-6-12-24-48-96 nm.
Press the [RANGE] key to select range. The range, range ring interval and pulselength appear at
the top left corner of the display.
1.13 Selecting the Pulselength
The pulselength in use is displayed at the upper-left position. Appropriate pulselengths are preset
to individual range scales and function keys. Therefore, you are not usually required to select them.
If you are not satisfied with the current pulselength settings, however, it is possible to change them
by the ECHO SIG menu as below. The pulselength is selectable on the ranges 0.5 to 24 nm.
1.13.1 Selecting pulselength 1 or 2
1. Press the [MENU] key to display the Main menu.
2. Press the [5] key twice to select ECHO SIG.
3. Press the [6] key or [7] key to select PULSE 1 or PULSE 2 as appropriate.
4. Press the [ENTER/SELECT] key.
5. Press the [MENU] key.
The indication of PULSE 1 or PULSE 2 alternately appears at the upper left corner of the display.
PULSE 1
1.
↑
2. 0. 5NM
S1 S2
3. 0.75-1.5NM S1 S2 M1
4. 3NM
S1 S2 M1 M2 M3
5. 6-12NM
M1 M2 M3 L 6.
24NM
M2 M3 L
Underlined is the default value on each range.
0.07 0.15 µs
0.07 0.15 0.3 µs
0.07 0.15 0.3 0.5 0.7 µs
0.3 0.5 0.7 1.2 µs
0.5 µs 0.7 1.2 µs
1.13.2 Presetting pulselengths 1 and 2
Pulselength 1 and 2 can be preset on the PULSE 1 and PULSE 2 in the ECHO SIG menu. A
longer pulse provides an increased detection range, but with reduced discrimination. If you need
discrimination in preference to detection, choose a shorter pulse
.
However short the radar satisfies
the detecting requirements of the IMO.
1. Press the [MENU] key.
2. Press the [5] key twice to display the ECHO SIG menu.
3. Press the [6] or [7] key as appropriate to select PULSE 1 or PULSE 2.
4. Press appropriate numeric key among 2-7 to select pulselength and range.
5. Press the [ENTER/SELECT] key.
6. Press the [MENU] key.
Содержание FR-1500 MARK-3
Страница 1: ...15 MULTI COLOR HIGH PERFORMANCE SHIPBORNE RADAR AND ARPA FR 1500 MARK 3 SERIES Back ...
Страница 13: ...xi CONFIGURATION OF FR 1500 MARK 3 SERIES RADARS VIDEO PLOTTER RP 17 or RP 180 ...
Страница 14: ...xii This page is intentionally left blank ...
Страница 62: ...This page is intentionally left blank ...
Страница 86: ...This page is intentionally left blank ...
Страница 118: ... 9 6 FR 1500 MARK 3 series interfacing diagram CHANNEL 2 OUTPUT TTM ...
Страница 119: ... 9 7 ...
Страница 123: ......
Страница 124: ......
Страница 125: ......