5. INSTALLATION AND INITIAL SETTINGS
5-5
5.2
Wiring
The FI-70 is able to display information from various sensors. The typical configuration
example shown in "SYSTEM CONFIGURATION" on page vi uses the optional data
converter (IF-NMEAFI) to show information from the analog sensors. The FI-70 is part
of a network, connected via a CAN bus/NMEA2000 backbone.
Note:
Unlike the FI-50 series, the FI-70 can not be daisy-chained. When retrofitting
from the FI-50 series, connect each FI-70 to the CAN bus (NMEA2000) backbone.
5.2.1
How to connect the unit
NMEA2000 port
Using the supplied cable assembly, connect the FI-70 to the CAN bus/NMEA2000
network backbone. The FI-70 must be on the same network as the sensors you wish
to connect to. Power is also supplied via the CAN bus/NMEA2000 backbone to the
FI-70.
Before retrofitting
FI-50 series
FI-70
After retrofitting
CAN bus (NMEA2000) backbone
CAN bus (NMEA2000) backbone
NMEA2000 port
Ground
terminal
Console rear
Cable assy.
(FI-70-0600, 6 m)
To CAN bus/NMEA2000
network backbone
Flat washer*
Ship’s ground terminal
Ground wire
(IV-1.25sq., local supply)
Terminal
screw*
*: Attached to FI-70, remove to install
Содержание FI-70
Страница 1: ...FI 70 OPERATOR S MANUAL www furuno com Model COLOR INSTRUMENT...
Страница 10: ...EQUIPMENT LISTS viii This page is intentionally left blank...
Страница 18: ...1 OPERATION AND CONTROLS OVERVIEW 1 8 This page is intentionally left blank...
Страница 44: ...3 ALARMS 3 10 This page is intentionally left blank...
Страница 62: ...4 SYSTEM MENU 4 18 This page is intentionally left blank...
Страница 76: ...5 INSTALLATION AND INITIAL SETTINGS 5 14 This page is intentionally left blank...
Страница 90: ...24 Apr 2017 H MAKI D 1...
Страница 91: ...24 Apr 2017 H MAKI D 2...
Страница 98: ......