3. ALARMS
3-6
3.7
Water Temperature Alarm
The water temperature alarm warns you when the temperature goes over or under the
set threshold. The average temperature may also be used as a threshold and is
calculated over one minute intervals.
1. Access the [Alarms] menu, using the procedure outlined on page 3-1.
2. Press the
software
keys to select [W Temp. Alarm], then press the
function
key.
3. [Alarm] is highlighted, press the
function
key.
4. Select [OFF], [Low], [High] or [Shear] as appropriate, then press the
function
key.
• [OFF]: Disable the alarm. Proceed to step 7.
• [Low]: Activates the alarm when the water temperature is lower than the set
threshold.
• [High]: Activates the alarm when the water temperature is higher than the set
threshold.
• [Shear]: Activates the alarm when the water temperature is higher than the set
threshold for more than one minute.
5. Press the
software
keys to select the threshold, then press the
function
key.
6. Press the
software
keys to set the threshold as appropriate, then press the
function
key to apply the changes.
7. Press the
Menu/Back
key twice to close the menu.
Содержание FI-70
Страница 1: ...FI 70 OPERATOR S MANUAL www furuno com Model COLOR INSTRUMENT...
Страница 10: ...EQUIPMENT LISTS viii This page is intentionally left blank...
Страница 18: ...1 OPERATION AND CONTROLS OVERVIEW 1 8 This page is intentionally left blank...
Страница 44: ...3 ALARMS 3 10 This page is intentionally left blank...
Страница 62: ...4 SYSTEM MENU 4 18 This page is intentionally left blank...
Страница 76: ...5 INSTALLATION AND INITIAL SETTINGS 5 14 This page is intentionally left blank...
Страница 90: ...24 Apr 2017 H MAKI D 1...
Страница 91: ...24 Apr 2017 H MAKI D 2...
Страница 98: ......