3-9
3.5 TEMP SETTING Menu
This menu sets up water temperature sensor.
DISP ALM TX/RX USER-1/2
SYSTEM
Select temperature sensor.
[-/+]: Change set, [EXIT (knob)]: Exit
TEMP SETTING
TEMP INPUT
:
SENSOR
TEMP ADJUST : +0.0 F(-20 +20)
TEMP READOUT : ON
TEMP GRAPH : OFF
TEMP COLOR : STD
TEMP SETTING menu
TEMP INPUT
Selects source of water temperature data; net sonde, sensor, NMEA or CIF.
TEMP ADJUST
Offsets water temperature indication to improve accuracy. Effective only for net sonde and water
temperature sensor. (-20.0 to +20.0
°
F in 0.1 step)
TEMP READOUT
Turns on/off water temperature indication.
TEMP GRAPH
Turns on/off temperature graph and selects graph scale.
OFF: No water temperature graph
NARROW: Graduation every 2
°
STD: Graduation every 2.5
°
(default setting)
EXPAND: Graduation every 5.0
°
TEMP COLOR
Selects the color of the temperature graph (standard, white, red, black, yellow).
Note:
Standard means the fifth color from the bottom of the color bar, including background
color in 16-color display; third color in 8-color display. Yellow means tenth (8-color display: sixth)
color from the bottom of the color bar.