2. WIRING
2-6
5. Fold back the armor by 5 mm, then put it between washers.
6. Catch the armor between two flat washers for grounding.
7. Apply sealant 1211 (supplied as installation material) to threads of the clamping
gland, and then fasten it tightly.
8. Determine the length of the cores considering their location on the terminal board
TB803, and then connect cores to TB803 by using the terminal opener.
9. Reattach the antenna cover, and then cover the gland junction with putty for wa-
terproofing.
Flat washer
5 mm
Vinyl sheath
Clamping gland
Gasket
5 mm
Trim the armor with width of washer (5 mm).
Wiring for WAGO connector
Press downward.
Terminal opener
WAGO Connector
Wire
Twist
Procedure
1. Twist the cores.
2. Press the terminal opener downward.
3. Insert the wire to hole.
4. Remove the terminal opener.
5. Pull the core to confirm that it is ecure.
Содержание FCR-2829W
Страница 14: ...EQUIPMENT LISTS xii This page is intentionally left blank ...
Страница 88: ...2 WIRING 2 54 This page is intentionally left blank ...
Страница 154: ...D 1 Y Hatai ...
Страница 155: ...D 2 14 Feb 2011 Y NISHIYAMA ...
Страница 156: ...D 3 16 Jun 2011 Y NISHIYAMA ...
Страница 157: ...D 4 Y Hatai ...
Страница 158: ...May17 07 R Esumi D 5 ...
Страница 159: ...13 Feb 2014 H MAKI D 6 ...
Страница 160: ...D 7 24 May 2012 Y NISHIYAMA ...
Страница 161: ...D 8 24 May 2012 Y NISHIYAMA ...
Страница 162: ...D 9 24 May 2012 Y NISHIYAMA ...
Страница 163: ...D 10 ...
Страница 164: ...D 11 ...
Страница 165: ...D 12 ...
Страница 166: ...D 13 12 May 2015 H MAKI ...
Страница 169: ...13 Jan 2012 Y NISHIYAMA 西山義浩 D 16 ...
Страница 170: ...13 Jan 2012 Y NISHIYAMA D 17 ...
Страница 171: ...D 18 ...