SYSTEM CONFIGURATION
ix
Back-up ECDIS connection
When setting up the radar as a ECDIS back-up, connect the radar and main ECDIS unit as shown
in the figure below.
Category of units
Antenna units: Exposed to the weather
Other units: Protected from the weather
EC-3000
PROCESSOR
UNIT
(ECDIS back-up)
Trackball Control Unit RCU-026
Radar Control Unit RCU-025
Select one
ECDIS Control Unit RCU-024
Radar Control Unit RCU-025
Trackball Control Unit RCU-026
(Max. 2)
Select one
Intelligent HUB
HUB-3000
Gateway network
equipment
(Radar, ECDIS, etc.)
Control Unit RCU-024
Trackball Control Unit RCU-026
Select one
ECDIS Control Unit RCU-024
Trackball Control Unit RCU-026
(Max. 2)
Select one
EC-3000
PROCESSOR
UNIT
(ECDIS main)
100-115/220-230 VAC
1ø, 50-60 Hz
100-115/220-230 VAC
1ø, 50-60 Hz
Sensor Adapter
MC-3000S
Serial
interface
Sensor Adapter
MC-3010A
Sensor Adapter
MC-3020D
Sensor Adapter
MC-3030D
Analog
interface
Digital in
interface
Digital out
interface
Serial 1 to 4
IEC 61162-2: Gyrocompass, AIS
IEC 61162-1: EPFS (Navigator),
SDME (Speed Log)
Digital Out 1 to 6
1: System Fail
2: Power Fail
3: Normal Close 1
4: Normal Close 2
5: Normal Open 1
6: Normal Open 2
Serial 5 to 7 (IEC 61162-1)
(EPFS2 (Navigator),
SDME3 (Speed Log),
Echo Sounder, Wind,
Alarm, Navtex, etc.)
VDR
LAN3
LAN1
LAN1
LAN2
LAN2
Radar Connection Box
RCB-002
Radar 1
Radar 2
100-230
VAC
AC/DC
Power Supply Unit
PR-240/PR-241
100-115/200-230 VAC
1ø, 50/60 Hz
Monitor Unit (Main)
VDR
Serial 1 to 4
IEC 61162-2: Gyrocompass, AIS
IEC 61162-1: EPFS (Navigator),
SDME (Speed Log)
Serial 5 to 8 (IEC 61162-1)
(EPFS2 (Navigator),
SDME3 (Speed Log),
Echo Sounder, Wind,
Alarm, Navtex, etc.)
Digital Out 1 to 6
1: System Fail
2: Power Fail
3: Normal Close 1
4: Normal Close 2
5: Normal Open 1
6: Normal Open 2
Monitor Unit (Sub)
Monitor Unit (Conning)
Monitor Unit
Digital In (ack)
Digital In (ack)
VDR
POWER SUPPLY UNIT
ANTENNA UNIT
TRANSCEIVER UNIT
100-230 VAC
1ø, 50-60 Hz
100-115/220-230 VAC
1ø, 50-60 Hz (for de-icer)
Sub Monitor
Serial8
• Solid lines indicate standard
supply equipment.
• Dashed lines indicate optional
or local supply equipment.
Intelligent
HUB
HUB-3000*
*: Use Switching
HUB-100 for
IEC61162-450 Ed.1
compliant network.
Содержание FAR 3220
Страница 201: ...D 1 31 Aug 2022 H MAKI...
Страница 202: ...D 2 31 Aug 2022 H MAKI...
Страница 203: ...D 3 31 Aug 2022 H MAKI...
Страница 204: ...D 4 31 Aug 2022 H MAKI...
Страница 205: ...D 5 13 May 2020 H MAKI...
Страница 206: ...D 6 13 May 2020 H MAKI...
Страница 207: ...D 7 13 May 2020 H MAKI...
Страница 208: ...D 8 13 May 2020 H MAKI...
Страница 209: ...D 9 31 Aug 2022 H MAKI...
Страница 210: ...D 10 31 Aug 2022 H MAKI...
Страница 211: ...D 11 13 May 2020 H MAKI...
Страница 212: ...D 12 13 May 2020 H MAKI...
Страница 213: ...D 13 29 Nov 2017 H MAKI...
Страница 214: ...D 14 29 Nov 2017 H MAKI...
Страница 215: ...24 Mar 2014 H MAKI D 15...
Страница 216: ...24 Mar 2014 H MAKI D 16...
Страница 217: ...D 17 8 Jun 2018 H MAKI...
Страница 218: ...D 18 8 Jun 2018 H MAKI...
Страница 219: ...D 19 8 Jun 2018 H MAKI...
Страница 220: ...D 20 11 Jan 2018 H MAKI...
Страница 221: ...D 21 11 Jan 2018 H MAKI...
Страница 222: ...D 22 11 Jan 2018 H MAKI...
Страница 223: ...D 23 11 Jan 2018 H MAKI...
Страница 224: ...D 24 11 Jan 2018 H MAKI...
Страница 225: ...D 25 11 Jan 2018 H MAKI...
Страница 226: ...D 26 14 Jun 2018 H MAKI...
Страница 227: ...D 27 14 Jun 2018 H MAKI...
Страница 228: ...D 28 14 Jun 2018 H MAKI...
Страница 229: ...D 29 28 Feb 2018 H MAKI...
Страница 230: ...D 30 8 Jun 2018 H MAKI...
Страница 231: ...D 31 13 Jan 2012 Y NISHIYAMA...
Страница 232: ...D 32 13 Jan 2012 Y NISHIYAMA...
Страница 233: ...D 33 13 Jan 2012 Y NISHIYAMA...
Страница 234: ...D 34 13 Jan 2012 Y NISHIYAMA...
Страница 235: ...D 35 6 Feb 2020 H MAKI...
Страница 236: ...D 36 25 Mar 2021 H MAKI...