background image

2.  WIRING

18

3. Pass the sealing nut, clamping claw and sealing insert onto the LAN cable in the order shown 

in the figure below. Connect the cable to the LAN connector. (Note the orientation of the seal-
ing insert when passing it onto the cable. Push the cable into the slit in the sealing insert.)

4. Set the sealing insert and clamping claw into the sealing nut then tighten the nut.
5. Tighten the sealing nut to fasten the LAN cable. The clearance between the lock nut and the 

sealing nut shall be 3 mm. The torque for the sealing nut shall be 1.8 - 2.0 N/m.

How to disconnect the LAN cable

Loosen the two screws on the gland to access the cable’s connector. A lock washer is fitted to the 
gland and the screws cannot be unfastened completely.

Sealing nut

LAN cable

Sealing insert
(Push cable into slit.)

Clamping claw

Clearance

Screw (2 pcs.)

Gland

Содержание DFF1-UHD

Страница 1: ...NETWORK FISH FINDER DFF1 UHD OPERATOR S MANUAL www furuno com Model...

Страница 2: ......

Страница 3: ...product according to local regulations for the disposal of industrial waste For disposal in the USA see the homepage of the Electronics Industries Alliance http www eiae org for the correct method of...

Страница 4: ...tall or operate the equipment WARNING WARNING Do not open the equipment Only qualified personnel should work inside the equipment Do not disassemble or modify the equipment Fire electrical shock or se...

Страница 5: ...stances shown below to prevent interference to a magnetic compass WARNING WARNING Do not open the equipment Only qualified personnel should work inside the equipment Turn off the power before beginnin...

Страница 6: ...sensor T 02MSB T 03MSB 5 2 WIRING 6 2 1 Wiring Outline 6 2 2 Transducer Cable Cable for External KP option 7 2 2 1 How to process the cables 7 2 2 2 How to connect the transducer cable 9 2 2 3 How to...

Страница 7: ...y for enhanced detection performance Fish size shown for depths up to 200 m and bottom discrimination Echoes are shown in high ultra definition thus echoes are displayed differently from those present...

Страница 8: ...1 50 60 Hz NETWORK FISH FINDER DFF1 UHD 12 24 VDC Transducer Rectifier PR 62 Speed Temperature Sensor ST 02MSB ST 02PSB Temperature Sensor T 02MTB T 02MSB T 03MSB NavNet Equipment TZT9 14 BB B265LH o...

Страница 9: ...31 1 kW plastic housing tank mount Thru hull pipe TFB 7000 000 022 532 Tank T 711 000 022 539 Cable Assembly MOD Z072 020 001 167 880 10 2 m for HUB 101 Cable Assembly MOD Z072 100 001 167 900 10 10 m...

Страница 10: ...tilated Mount the unit where shock and vibration are minimal Keep the unit away from electromagnetic field generating equipment such as motors and gen erators Leave slack in cables for maintenance and...

Страница 11: ...lar However the sensor must not be located where it may be damaged in dry docking operations Select a place apart from equipment generating heat Select a place in the forward direction viewing from th...

Страница 12: ...T 02MTB Fix the cable at a convenient location with cable clamp When the cable is led in through the transom board make a hole of approx 17 mm in diameter to pass the connector After passing the cable...

Страница 13: ...ide Sensor Holder T 02MSB T 03MSB Mounting procedure 1 Drill a hole of 21 mm in diameter in the mounting location 2 Pass the sensor cable through the hole 3 Pass gasket washer and locknut onto cable i...

Страница 14: ...ake the length of the wire as short as possible For FRP vessels install a ground plate that mea sures about 20 cm by 30 cm on the outside of the hull bottom and connect the ground wire there DFF1 UHD...

Страница 15: ...he transducer cable can be removed if it interferes with treatment of the cable How to process the transducer cable CM265LH B265LH Name Type Code No Qty Upset UI Screw B M4 20 000 163 756 10 2 Super G...

Страница 16: ...to each core 2 Remove the armor 170 mm and cut off the vinyl sheath 90 mm 3 Remove 5 mm of the vinyl sheath from the cores then connect each crimp on lug attached at step 2 as shown below 4 Wrap the...

Страница 17: ...xternal KP go to section 2 2 3 1 Open the cover Grasp the cover at two sides spread the cover slightly and lift 2 Loosen five screws to remove the shield cover 3 Detach the two WAGO connectors TB3 TB4...

Страница 18: ...following the instructions in the figure below and the intercon nection diagram 8 Attach the WAGO connectors 9 Refasten the clamp fixing plate referring to the table below for how to orient the plate...

Страница 19: ...g to steps 1 3 in section 2 2 2 2 Unfasten the lock nut of the inside the unit to detach the super gland 3 Unfasten two screws to remove the clamp fixing plate 4 Unfasten two screws securing the clamp...

Страница 20: ...erial inside the unit 7 Using the two screws removed at step 5 fasten the upper two holes of the supplied rainproof ing panel Nut material Rainproofing panel Clamp Clamp fixing plate Rainproofing pane...

Страница 21: ...2 0 N m 9 Set the nut material removed at step 6 inside the unit align its two protrusions with the lower holes on the rainproofing panel Use the remaining two screws removed at step 5 to fasten the l...

Страница 22: ...per gland of the cable for the external KP unfasten the lock nut from the super gland then pass the cable through the super gland See page 8 for how to treat the cable end After passing the cable for...

Страница 23: ...and connect the cable to J12 on the PWRTX board Be sure the cable does not contact TB4 Note For cable MPYC 2 tape the vinyl sheath of the cable approx 6 to 7 turns where it lies in the cable clamp and...

Страница 24: ...ING 16 14 Attach the supplied EMI core GRFC 10 to the cable for the external KP approx 100 mm from the super gland 15 Attach the shield cover and close the outer cover Super gland for ext KP EMI core...

Страница 25: ...he LAN connector then remove the sealing insert and clamping claw 2 Detach the sealing insert from the clamping claw as shown below Sealing nut Clamping claw Insert seal Sealing insert Super gland Sea...

Страница 26: ...and clamping claw into the sealing nut then tighten the nut 5 Tighten the sealing nut to fasten the LAN cable The clearance between the lock nut and the sealing nut shall be 3 mm The torque for the s...

Страница 27: ...h 2 referring to the table below ON Use IP address assigned by DHCP 2 IP address no OFF Set the 1 switch to OFF to set IP address See the table on the next page for IP address assignment 3 Restore def...

Страница 28: ...LED on the cover of the DFF1 UHD lights or blinks according to equipment state as described in the table below LED state and meaning 2 Host name IP address OFF ES092002 172 031 092 002 ON ES092003 172...

Страница 29: ...h Cleaning the network fish finder s cabinet Dust or dirt on the cabinet may be removed with a dry cloth Do not use chemical based cleaners to clean the cabinet they can remove markings and damage the...

Страница 30: ...the NavNet series device You can restore all default settings or restore those other than transducer and LAN This procedure should only be performed by a suitably qualified FURUNO technician 1 Disconn...

Страница 31: ...Type 5 Sheath Type 6 Shielding Type C Steel Y Anticorrosive vinyl sheath SLA SLA DPYCY Diameter Diameter DPYC 1 5 1 5mm2 1 56mm 11 7mm DPYC 2 5 2 5mm2 2 01mm 12 8mm DPYC 4 4 0mm2 2 55mm 13 9mm DPYC 6...

Страница 32: ...2403 5 2403 10 1621 40 476 100 222 400 58 1200 34 2 INTERFACE 2 1 I O port Network 1 port Temp speed sensor 1 port External KP 1 port external KP kit option 2 2 Network method Ethernet 10Base T 100Ba...

Страница 33: ...W 5X20 SUS304 000 162 608 10 4 LAN LAN CABLE ASSEMBLY MOD Z072 050 000 167 176 10 1 MJ CABLE ASSEMBLY MJ A3SPF0013 035C 5A 000 157 939 10 1 DOCUMENT OPERATOR S MANUAL OM 20400 000 177 244 1 1 CODE NUM...

Страница 34: ...7 Dec 2012 Y NISHIYAMA...

Страница 35: ...IN DRAIN MJ A3SPF GRN BLK WHT 5A 1 2 3 5 6 PR 62 RECTIFIER MJ A3SPF0013 035C 3 5m 12 24VDC GND IV 2sq 1 TEMP SPEED SENSOR ST 02MSB PSB T 02MTB MSB T 03MSB IV 2sq 1 2 10m 2 8 8 RJ45 RJ45 ETHERNET HUB H...

Страница 36: ...cient Otherwise the invoice with serial number name and stamp of the dealer and date of purchase is shown For the Onboard Warranty your FURUNO certified dealer will take care of all registrations 5 Wa...

Страница 37: ...or its authorized dealer at the time of request for warranty service This warranty is valid for installation of products manufactured by Furuno Electric Co hereafter FURUNO Any purchases from brick a...

Страница 38: ......

Страница 39: ......

Страница 40: ...Dealer Printed in Japan Elemental Chlorine Free The paper used in this manual is elemental chlorine free 9 52 Ashihara cho Nishinomiya 662 8580 JAPAN All rights reserved Pub No OME 20400 B DAMI DFF1...

Отзывы: