2. WIRING
11
10. Tighten the sealing nut according to the information in the table below.
11. Reattach the shield cover and close the outer cover.
2.2.3
How to connect the transducer cable, cable for external KP
1. Remove the cover, shield cover and WAGO connectors, referring to steps 1-3 in section 2.2.2.
2. Unfasten the lock nut of the inside the unit to detach the super gland.
3. Unfasten two screws to remove the clamp fixing plate.
4. Unfasten two screws securing the clamp. Save the screws for later use.
5. Unfasten the four screws securing the rainproofing panel. You may discard the panel. Save
the screws for later use.
Transducer
Clearance
Torque
CM265LH
4 mm
1.8 - 2.0N/m
B265LH
2 mm
Clearance
Super gland
Lock nut
Clamp
Clamp fixing plate