1. MOUNTING
1-6
5. After screwing the transducer into the main shaft, fasten two socket-screws (M6x10,
supplied).
Coat 50 mm of shaft
with grease.
Waterproofing
attachment
Hold here with pipe wrench.
50mm
140mm
Socket-set screw
M6x10, 2 pcs.
Rotate trans-
ducer to screw in
main shaft.
Note: Screw shaft 50 mm
into transducer flange.
Fastening main shaft to transducer
6. Clean the top of the shaft with alcohol, install the waterproofing attachment and apply
Lock-tight (supplied) to the socket screw.
Clean with alcohol
here.
30 mm
Shaft
Waterproofing
attachment
M6 socket-set screw
(Apply Lock-tight.)
Cleaning the shaft