APPENDIX
AP-4
Installation when retraction tank is 600 mm to 750 mm long
1. Follow the steps 1 to 5 in the previous procedure.
2. Modify the transducer travel to 450 mm by changing the upper limit switch position.
Upper limit switch.
Move the upper limit switch
to modify to 450 mm travel.
3. Assemble the hull unit completely, taking the following points into account. Refer to
chapter 1 for details of assembling and installation.
a)
The tank guide should be installed at a position 162 mm above the top of the
transducer flange.
Tank guide
162 mm
*
*Measure from the inside of the tank guide.
b)
The shaft retainer should be in contact with the waterproofing attachment.