3-1
3. ADJUSTMENTS
WARNING
ELECTRICAL SHOCK HAZARD
Do not open the equipment unless totally
familiar with electrical circuits and service
manual.
Only qualified personnel should work inside
the equipment.
3.1 Measuring
TX
Output
1. Set the controls of the control unit as follows.
Range: 400 m
Output: 10 (Max.)
Vertical Beam width: Wide
Tilt: 0°
Pulselength: 10 (Max.)
2. Connect the oscilloscope across Vout + and Vout – jacks on the TAMP boards
(10P6614) and measure the peak-to-peak voltage of the TX signal at the center point of
its pulselength.
Waveform measured across Vout + and Vout -
Channel No.
Test Point Location
Measuring TX output signal