1. MOUNTING
1-5
3. Wrap the sheath end with vinyl tape to pass the cable through the main shaft, and then
remove sheath of transducer cable at the length of “main shaft 70 mm.”
Note:
Care should be taken not to damage inner wires when cutting the cable sheath,
only paper tape exists between the cable sheath and inner wires.
Main shaft 70 mm
Use suitable roller knife to cut sheath.
Transducer cable
4. After screwing the transducer into main shaft, fasten two socket-set screws (M6x10,
supplied) to fasten the main shaft to the transducer.
Note:
The transducer should be screwed into the main shaft by 50 mm.
Grease shaft 50 mm.
Rotate transducer
to screw it into
main shaft.
Socket-set screw
M6X10, 2 pcs.
Hold this portion
with pipe wrench.
When it is difficult to pass the
transducer cables through the
flat washers, gasket and the
cable gland, unbind the
transducer cables and pass
them one by one.
Cable gland
Flat
washer
Gasket
Installing transducer
Содержание CSH-5L
Страница 1: ...PRINTED IN JAPAN COLOR SCANNING SONAR CSH 5L ...
Страница 18: ...1 MOUNTING 1 10 ...
Страница 19: ...1 MOUNTING 1 11 ...
Страница 64: ......
Страница 74: ......
Страница 75: ......
Страница 76: ......
Страница 77: ......
Страница 78: ......
Страница 79: ......
Страница 80: ......
Страница 81: ......
Страница 82: ......
Страница 83: ......
Страница 84: ......
Страница 85: ......
Страница 86: ......
Страница 87: ......
Страница 88: ......
Страница 89: ......
Страница 90: ......
Страница 91: ......
Страница 92: ......
Страница 95: ......
Страница 96: ......
Страница 97: ......
Страница 98: ......
Страница 99: ......
Страница 100: ......