6. MAINTENANCE, TROUBLESHOOTING
6-7
6.8
Diagnostics
6.8.1
How to perform a full system test
The [Tests] function conducts a comprehensive test on the transceiver unit, monitor
unit and the control panel.
To begin a diagnostic test, do the following:
1.
Referring to section 5.5, open the [System] menu.
2.
Press
T
or
S
to select [Tests], then press
X
. The system test results window ap-
pears.
3.
After a few moments, the hardware and software results should appear in the win-
dow. Check that no items show the result as "NG" (Not Good). If any item shows
"NG" contact your local dealer for advice.
4.
Press each key on the panel and remote control. The indication for each key
should change from "0" to "1" when the key is pressed. When the key is released,
the indication should change back to "0". If the indication does not change, there
may be a problem with the control panel. Contact your dealer for advice.
5.
To exit the diagnostic test, press the
MENU
key three times, in quick succession.
Press MENU key 3 times to exit.
Hardware and
software test
results.
Control panel and
remote control
key test results.
RX_TEST(RX_ONLY)
: 64.3/63.8
DIGI DIPSW : 00000101 (05)
DRV DIPSW : 0000 (0)
CH-500
CH-600
Содержание CH-500
Страница 12: ...SYSTEM CONFIGURATION x This page is intentionally left blank ...
Страница 38: ...1 OPERATIONAL OVERVIEW 1 26 This page is intentionally left blank ...
Страница 58: ...2 HORIZONTAL MODE 2 20 This page is intentionally left blank ...
Страница 96: ...6 MAINTENANCE TROUBLESHOOTING 6 10 This page is intentionally left blank ...
Страница 106: ...FURUNO CH 500 600 SP 4 E1354S01C M 180319 This page is intentionally left blank ...
Страница 109: ......