Furuno CAN bus Network Design Guide
8
Termination with MFD
The MFD unit is terminated with a terminator as shown in Fig.23, because the unit does not
have the internal terminator.
Fig.23 Termination with MFD
Internal Terminator
Furuno CAN bus devices, DRS, FI-50, GP-330B, SC-30, and WS-200 have an internal
terminator, so these devices can be connected to the backbone cable as shown in Fig.24.
By connecting the device to the backbone cable, the cable length between the T-connector
and the device can be extended more than 6 m.
Fig.24 Using internal terminator at both ends of backbone cable
To activate the internal terminator;
(a) DRS
The resistor assembly, 120 OHM-1007#24-L50, C/N: 000-167-746 is connected between
#5 and #6 of J603 in the radome antenna and #4 and #5 of TB102 in the open type
antenna.
Fig.25 Terminator in DRS2D/4D
Fig.26 Terminator in DRS4A/6A/12A/25A
GP-330B
Device
Device
Device
FI-50
Power supply
J603
TB102
CAN bus cable or
NMEA2000 cable
Female Terminator
Backbone cable
to rest of bus
In-line Terminator
Type: FRU-0505-FF-IS
C/N: 000-172-037-10
#5 & #6
#4 & #5
or