background image

the furman merit series

Furman Sound, LLC

1690 Corporate Circle 

Petaluma, California 94954-6919 USA

Phone: 707-763-1010  Fax: 707-763-1310  

Web: www.furmansound.com  

E-mail: info@furmansound.com

111904-D

sPeCifiCatiOns

Current rating:

15 amps (1800 watts at 120 VAC)

Line Cords:

6 ft. captive, 14 AWG, with 3-conductor 
Edison Plug

Lamps (if present):

2 x 5 watts

AC Voltmeter (if present):

Range 60 to 150 VAC; ac/- 2 VAC

Operating Voltage:

90 to 140 VAC

Spike Protection Modes (M-8, M-8L, M-8D):

Line to neutral

Spike Clamping Voltage(M-8, M-8L, M-8D):

188 Vpk @ 3,000 amps, (133 VAC RMS) 
 

Maximum surge current (M-8, M-8L, M-8D):

4,500 amps

Noise attenuation (M-8, M-8L, M-8D):

Transverse mode: Greater than 50 dB, 1 to 
100 MHz

Mechanical:

Dimensions(M-8, M-8L, M-8D): 

1.75” H x 19” W x 7.5” D. 

 

Dimensions(M-10): 

1.75” H x 19” W x 3.96” D. 

Weight: 5 lbs  (2.3 kg).  
Construction: Steel chassis, black painted

Power Consumption:

M-8, 6 watts 
M-8L, 14 watts
M-8D, 14 watts
M-10, 0 watts
 

Safety Agency Listings:

TUV, TUV-C

Содержание RM-8

Страница 1: ...the furman merit series...

Страница 2: ...Surge Spike Protection Eight rear panel outlets and one front panel outlet 15 amp rating with circuit breaker One year limited warranty Two retractable incandescent light fixtures with dimmer control...

Страница 3: ...sources such as radiators heat registers stoves or other appliances that produce heat 4 The Merit Series units should only be connected to a 120 VAC 60Hz 15 amp grounded electrical outlet Do not defea...

Страница 4: ...res 5 5 feet of 14 gauge heavy duty power cable O P E RAT I O N Retractable Rack Lights and Dimmer Control The M 8L and M 8D utilize a dimmer control for the two retractable front panel light tubes Th...

Страница 5: ...rby radio transmitters certain kinds of lighting electric motors and other sources Because noise occurs at higher frequencies than the 50 or 60 Hz AC line it can be effectively reduced through use of...

Страница 6: ...s or any part thereof whether based on contract tort strict liability or otherwise Under no circumstances whether based on this Limited Warranty or otherwise shall Manufacturer be liable for incidenta...

Страница 7: ...ditional Switched Outlet Light Switch Circuit Breaker Power Switch Voltmeter Additional Switched Outlet M 8D Rack Lights Dimmer Control Light Switch Circuit Breaker Power Switch Rack Lights Additional...

Страница 8: ...e 60 to 150 VAC accuracy 2 VAC Operating Voltage 90 to 140 VAC Spike Protection Modes M 8 M 8L M 8D Line to neutral Spike Clamping Voltage M 8 M 8L M 8D 188 Vpk 3 000 amps 133 VAC RMS Maximum surge cu...

Отзывы: