Furman RM-8 Скачать руководство пользователя страница 4

the furman merit series

F E A T U R E S

M-10

The M-10 power distributor is a convenient way 

to power your rack.  It provides 10 outlets on its 

rear panel and carries a 15 amp rating with a 

circuit breaker.

M-8

The M-8 power conditioner provides 9 switched 

outlets for powering equipment.  It not only  

protects anything plugged into it from spikes 

and surges, but also has a built in AC noise 

filter to rid the system of RFI / EMI interference.  

This allows equipment to function better and 

last longer.

 

M-8L 

In addition to features of the M-8, the M-8L 

features incandescent rack lights.  A dimmer 

control for the rack lights allows the user to 

adjust the level of illumination or simply switch 

the lights off.  The M-8L has a master switch for 

all outlets that glows red when the power is on. 

The front-panel circuit breaker can be quickly 

and easily reset should the unit be overloaded. 

The M-8L also features 5.5 feet of 14 gauge 

heavy-duty power cable. 

M-8D

In addition to all the features of the M-8 and 

M-8L, the M-8D offers a laboratory precision 

digital meter that displays incoming voltage in 1-

volt steps.  The voltmeter’s accuracy is ±2 volts.  

The M-8D has a master switch for all outlets 

that glows red when the power is on. The front-

panel circuit breaker can be quickly and easily 

reset should the unit be overloaded. The M-8D 

also features 5.5 feet of 14 gauge heavy-duty 

power cable. 

O P E R AT I O N

Retractable Rack Lights and Dimmer Control: 

The M-8L and M-8D utilize a dimmer control 

for the two retractable front panel light tubes. 

The dimmer knob controls the brightness 

of both light fixtures. Turn it clockwise to 

increase brightness; turn it counterclockwise 

to decrease brightness.  When the lights 

are not in use, we recommend turning the 

racklight’s switch to off to better maximize the 

life of the bulbs.

Digital Voltmeter:  (M-8D)

Furman’s digital voltmeter continually 

measures incoming voltages within a typical 

tolerance of +/-2VAC.  It should be noted 

that the voltage reading is incoming.  No 

adjustment should be necessary on these 

units. 

NOTE: The Merit Series units do not 

compensate for high or low line voltage. If 

you frequently move your rack to different 

locations, derive power from generators, use 

long extension cords, travel internationally, or 

are in an area prone to brownouts, you may 

benefit from the use of one of Furman’s AC 

Line Voltage Regulators.  

On/Off Rocker Switch: 

This 15 amp capacity power switch is 

specifically designed to stand up to the 

enormous high inrush current demands of 

many Power Amplifiers. Additionally, the semi-

transparent rocker lights when switched to the 

“ON” position.  

T R O U B L E S H O O T I N G    G U I D E

1.) Symptom: No power to the AC outlets.

Possible Cause: Circuit breaker has tripped 

due to excessive load.

Action Needed: Remove one piece of 

equipment from the Merit Series unit, and push 

the square re-set tab into the Circuit breaker 

bezel.

3

Содержание RM-8

Страница 1: ...the furman merit series...

Страница 2: ...Surge Spike Protection Eight rear panel outlets and one front panel outlet 15 amp rating with circuit breaker One year limited warranty Two retractable incandescent light fixtures with dimmer control...

Страница 3: ...sources such as radiators heat registers stoves or other appliances that produce heat 4 The Merit Series units should only be connected to a 120 VAC 60Hz 15 amp grounded electrical outlet Do not defea...

Страница 4: ...res 5 5 feet of 14 gauge heavy duty power cable O P E RAT I O N Retractable Rack Lights and Dimmer Control The M 8L and M 8D utilize a dimmer control for the two retractable front panel light tubes Th...

Страница 5: ...rby radio transmitters certain kinds of lighting electric motors and other sources Because noise occurs at higher frequencies than the 50 or 60 Hz AC line it can be effectively reduced through use of...

Страница 6: ...s or any part thereof whether based on contract tort strict liability or otherwise Under no circumstances whether based on this Limited Warranty or otherwise shall Manufacturer be liable for incidenta...

Страница 7: ...ditional Switched Outlet Light Switch Circuit Breaker Power Switch Voltmeter Additional Switched Outlet M 8D Rack Lights Dimmer Control Light Switch Circuit Breaker Power Switch Rack Lights Additional...

Страница 8: ...e 60 to 150 VAC accuracy 2 VAC Operating Voltage 90 to 140 VAC Spike Protection Modes M 8 M 8L M 8D Line to neutral Spike Clamping Voltage M 8 M 8L M 8D 188 Vpk 3 000 amps 133 VAC RMS Maximum surge cu...

Отзывы: