TM250 / P/N 250TM-(xxx)-(xxx)
Operation and Installation
14
Document No.: 03.310.010.71e / Revision: 2.10
2.4
Configuration Page
The configuration view may be selected by the use of the
Button.
The desired menu item can then be selected by one or multiple presses
of the minus key
. Selection goes repeatedly from top to bottom. The
blue background indicates the active menu item that can be adjusted
with the
key. More details on each menu item can be found in the
following segments.
2.4.1
Audio
In addition to the visual warnings audio alerts can also be raised. The
following settings for when and how audio alerts will be raised are
offered:
once ........... For each traffic object, an audio alert is raised only once
when it is recognized as a threat
repeat ......... The audio alert continues as long as the target poses a
threat or the user confirms (and thus silences) the alarm with
the
or
key. Any alert needs to be confirmed
separately. Depending on the threat level the audio alerts
will be repeated every 4 seconds for the approach alarm,
every 2 seconds for a potential collision threat and once per
second for an active collision threat.
disabled ..... No audio alert is raised.