FT-C Vertical Electric Thermal Fluid Heater Manual 12 2013 ISSUE 1
Page 49
3
3.8
REQUIRED FLOW THROUGH THE HEATER
1. Maintenance of sufficient flow through the thermal fluid heater and system at all times of
operation is critical. See table for recommended standard flow rates.
2. Note pressure gauge readings at start-up. Record readings in a log book and contact the Fulton
service department immediately in the event of abnormal readings. Failure to take action when
fluid flow is reduced may result in serious and rapid degradation of the fluid with possible
damage to the heater.
RECOMMENDED FLOW RATE
(m
3
/hr)
PRESSURE DROP ACROSS HEATER
(barg)
FT-0080C
11.4
1.7
FT-0120C
17
1.9
FT-0160C
22.7
1.4
FT-0240C
34
2.1
FT-0320C
56.8
1.7
FT-0400C
56.8
1.7
FT-0600C
85.2
1.8
FT-0800C
113.6
1.8
FT-1000C
139
1.2
FT-1200C
167
1.9
FT-1400C
182
1.9