background image

En-6

To Stop Operation

Press the “START/STOP” button.

The OPERATION Indicator Lamp (green) will go out.

About AUTO CHANGEOVER Operation

AUTO:

When AUTO CHANGEOVER operation first selected, the fan will ope-
rate at very low speed for about 1 minute, during which time the unit
detects the room conditions and selects the proper operating mode.

If the difference between temperature setting and actual room tem-
perature is more than +2 °C

Cooling or dry operation
(Monitor operation may be selected if the outdoor temperature is
low.)

If the difference between temperature setting and actual room tem-
perature is within ±2 °C

Monitor operation

If the difference between temperature setting and actual room tem-
perature is more than -2 °C

Heating operation
(Monitor operation may be selected if the outdoor temperature is
high.)

When the air conditioner has adjusted your room’s temperature to near
the temperature setting, it will begin monitor operation. In the monitor
operation mode, the fan will operate at low speed. If the room tem-
perature subsequently changes, the air conditioner will once again
select the appropriate operation (Heating, Cooling) to adjust the tem-
perature to the value set in the temperature.

(The monitor operation range is ±2 °C relative to the temperature set-
ting.)

If the mode automatically selected by the unit is not what you wish,
select one of the mode operation (HEAT, COOL, DRY, FAN).

About Mode Operation

Heating:

Use to warm your room.

When Heating mode is selected, the air conditioner will operate at very
low fan speed for about 3 to 5 minutes, after which it will switch to the
selected fan setting. This period of time is provided to allow the indoor
unit to warm up before beginning full operation.

When the room temperature is very low, frost may form on the outside
unit, and its performance may be reduced. In order to remove such
frost, the unit will automatically enter the defrost cycle from time to
time. During Automatic Defrosting operation, the OPERATION Indica-
tor Lamp (green) will flash, and the heat operation will be interrupted.

After the start of heating operation, it takes some time before the room
gets warmer.

Cooling:

Use to cool your room.

Dry:

Use for gently cooling while dehumidifying your room.

You cannot heat the room during Dry mode.

During Dry mode, the unit will operate at low speed; in order to adjust
room humidity, the indoor unit’s fan may stop from time to time. Also,
the fan may operate at very low speed when adjusting room humidity.

The fan speed cannot be changed manually when Dry mode has been
selected.

Fan:

Use to circulate the air throughout your room.

During Heating mode:

Set the temperature to a temperature set-
ting that is higher than the current room
temperature. The Heating mode will not
operate if the temperature is set lower
than the actual room temperature.

During Cooling/Dry mode:

Set the temperature to a temperature set-
ting that is lower than the current room
temperature. The Cooling and Dry modes
will not operate if the temperature is set
higher than the actual room temperature,
the fan alone will operate.

During Fan mode:

You can not use the unit to heat and cool
your room.

OPERATION

9378629042_OM_en.p65

21/9/10, 17:00

6

Содержание UTY-LRHYM

Страница 1: ...MPLOI AFIN DE POUVOIR VOUS Y RÉFÉRER ULTÉRIEUREMENT GUARDE ESTE MANUAL PARA PODERLO CONSULTAR EN EL FUTURO CONSERVARE QUESTO MANUALE PER OGNI EVENTUALE FUTURO RIFERIMENTO ΚΡΑΤΗΣΤΕ ΤΟ ΕΓΧΕΙΡΙ ΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ GUARDE ESTE MANUAL PARA CONSULTA POSTERIOR СОХРАНИТЕ НАСТОЯЩЕЕ РУКОВОДСТВО ДЛЯ БУДУЩИХ ССЫЛОК BU KILAVUZU DAHA SONRA BAfiVURMAK ÜZERE SAKLAYIN P N9378629042 IR RECEIVER UNIT for DUCT T...

Страница 2: ...r place objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of air conditioners Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Do not pull power supply cord Turn off power source when not using the unit for extended periods Always turn off the electrical breaker whenever cl...

Страница 3: ...to OFF timer within a 24 hour period SLEEP TIMER When the SLEEP button is pressed during Heating mode the air conditioner s temperature setting is gradually low ered during the period of operation during cooling mode the temperature setting is gradually raised during the pe riod of operation When the set time is reached the unit automatically turns off WIRELESS REMOTE CONTROLLER The Wireless Remot...

Страница 4: ...ously To stop the test operation mode press the START STOP button to stop the air condi tioner Remote controller 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Display 1 MODE button 2 SET TEMP button 3 10 C HEAT button 4 ECONOMY button 5 SLEEP button 6 FAN button 7 START STOP button 8 SET button Vertical 9 SET button Horizontal 0 SWING button A TIMER MODE button B TIMER SET button C CLOCK ADJUST button D ...

Страница 5: ...ssed to change the time quickly in 10 minute increments 3 Press the CLOCK ADJUST button again This completes the time setting and starts the clock To Use the Remote Controller The Remote Controller must be pointed at remote control signal receiver to oper ate correctly Operating Range About 5 m When a signal is properly received by the receiver unit control panel some lamp will be flashed If no la...

Страница 6: ...ut 3 seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches that of the temperature setting the fan speed becomes slower Fan The fan runs at the low fan speed The fan will o...

Страница 7: ...ed the air conditioner will operate at very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before beginning full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatica...

Страница 8: ...e desired OFF time or ON time Set the time while the time display is flashing the flashing will continue for about 5 seconds button Press to advance the time button Press to reverse the time About 5 seconds later the entire display will reappear To Use the Program timer 1 Press the START STOP button if the unit is already operating proceed to step 2 The receiver unit control panel s OPERATION Indi...

Страница 9: ...ur 1 hour 30 minutes Set time During Cooling Dry operation When the SLEEP timer is set the temperature setting is auto matically raised 1 C every 1 hour When the temperature has been raised a total of 2 C the temperature setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting During Heating operation When the S...

Страница 10: ...he set temp under cooling mode and lower than set temp under heating mode Therefore the economy mode is able to save more energy than other normal mode 10 C HEAT OPERATION The room temperature can be maintained at 10 C by pressing the 10 C HEAT button so as to prevent the room temperature from falling too far To use 10 C HEAT OPERATION Press the 10 C HEAT button The OPERATION indicator lamp green ...

Страница 11: ...e The remote controller resets to signal code A when the batteries in the remote controller are replaced If you use a signal code other than signal code A reset the signal code after replacing the batteries If you do not know the air conditioner signal code setting try each of the signal codes until you find the code which operates the air conditioner CLEANING AND CARE When used for extended perio...

Страница 12: ...Automatic Defrosting operation When Heating operation is started fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the temperature setting the outdoor unit will stop and the in door unit will operate at very low fan speed If you wish to warm the room further set the temperature for a higher setting During Heating opera...

Страница 13: ...s on the heat pump princi ple absorbing heat from outdoor air and transferring that heat to indoor unit As a result the operating perform ance is reduced as outdoor air temperature drops If you feel that insufficient heating performance is being pro duced we recommend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room...

Страница 14: ...ut provided by your units and use the units in the way that best matches your family s lifestyle If you discover that 1 or more units delivers a low level of cooling or heating during simultaneous operation we recommend that you stop simultaneous operation of the multiple units Operation cannot be done in the following different op erating modes If the indoor unit is instructed to do an operating ...

Страница 15: ... ...

Страница 16: ......

Отзывы: