background image

En-11

TROUBLESHOOTING

Symptom

Doesn’t operate immedi-
ately:

Noise is heard:

Smells:

Mist or steam is
emitted:

Airflow is weak or stops:

Water is produced from
the outdoor unit:

Problem

If the indoor unit is stopped and then immediately started again,
the compressor will not operate for about 3 minutes, in order to
prevent fuse blowouts.

Whenever the electrical breaker is turned off then on again the
protection circuit will operate for about 3 minutes, preventing unit
operation during that period.

During operation or  immediately after stopping the unit, the sound
of water flowing in the air conditioner’s piping may be heard.
Also, noise may be particularly noticeable for about 2 to 3 min-
utes after starting operation (sound of refrigerant flowing).

During operation, a slight squeaking sound may be heard. This is
the result of minute expansion and contraction of the front panel
due to temperature changes.

During Heating operation, a sizzling sound may be heard occasional.
This sound is produced by the Automatic Defrosting operation.

Some smell may be emitted from the indoor unit. This smell is
the result of room smells (furniture, tobacco, etc.) which have
been taken into the indoor unit.

During Cooling or Dry operation, a thin mist may be seen emitted
from the indoor unit. This results from the sudden Cooling of
room air by the cool air emitted from the indoor unit, resulting in
condensation and misting.

During Heating operation, the outdoor unit’s fan may stop, and
steam may be seen rising from the unit. This is due to Automatic
Defrosting operation.

When Heating operation is started, fan speed is temporarily very
low, to allow internal parts to warm up.

During Heating operation, if the room temperature rises above
the temperature setting, the outdoor unit will stop, and the in-
door unit will operate at very low fan speed. If you wish to warm
the room further, set the temperature for a higher setting.

During Heating operation, the indoor unit will temporarily stop
operation (between 7 and 15 minutes) as the Automatic Defrost-
ing mode operates. During Automatic Defrosting operation, the
OPERATION Indicator Lamp will flash.

During Dry mode, the indoor unit will operate at low speed; in
order to adjust room humidity, the indoor unit’s fan may stop
from time to time. Also, the fan may operate at very low speed
when adjusting room humidity.

During QUIET operation, the fan will operate at very low speed.

In the monitor of AUTO operation, the fan will operate at very
low speed.

In case of Multi-type unit, if multiple units are operated in differ-
ent operation modes as shown below, the units operated after-
ward will stop and the OPERATION indicator lamp (green) will flash.

Heating mode and cooling mode (or dry mode)

Heating mode and fan mode

During Heating operation, water may be produced from the out-
door unit due to Automatic Defrosting operation.

See Page

12

12

12

6

5

6

13

12

NORMAL

FUNCTION

 WARNING

• In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical
  breaker and consult authorized service personnel.
• Merely turning off the unit’s power switch will not completely disconnect the unit from the power source.
• Always be sure to turn off the electrical breaker to ensure that power is completely off.

9378629042_OM_en.p65

21/9/10, 17:00

11

Содержание UTY-LRHYM

Страница 1: ...MPLOI AFIN DE POUVOIR VOUS Y RÉFÉRER ULTÉRIEUREMENT GUARDE ESTE MANUAL PARA PODERLO CONSULTAR EN EL FUTURO CONSERVARE QUESTO MANUALE PER OGNI EVENTUALE FUTURO RIFERIMENTO ΚΡΑΤΗΣΤΕ ΤΟ ΕΓΧΕΙΡΙ ΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ GUARDE ESTE MANUAL PARA CONSULTA POSTERIOR СОХРАНИТЕ НАСТОЯЩЕЕ РУКОВОДСТВО ДЛЯ БУДУЩИХ ССЫЛОК BU KILAVUZU DAHA SONRA BAfiVURMAK ÜZERE SAKLAYIN P N9378629042 IR RECEIVER UNIT for DUCT T...

Страница 2: ...r place objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of air conditioners Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Do not pull power supply cord Turn off power source when not using the unit for extended periods Always turn off the electrical breaker whenever cl...

Страница 3: ...to OFF timer within a 24 hour period SLEEP TIMER When the SLEEP button is pressed during Heating mode the air conditioner s temperature setting is gradually low ered during the period of operation during cooling mode the temperature setting is gradually raised during the pe riod of operation When the set time is reached the unit automatically turns off WIRELESS REMOTE CONTROLLER The Wireless Remot...

Страница 4: ...ously To stop the test operation mode press the START STOP button to stop the air condi tioner Remote controller 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Display 1 MODE button 2 SET TEMP button 3 10 C HEAT button 4 ECONOMY button 5 SLEEP button 6 FAN button 7 START STOP button 8 SET button Vertical 9 SET button Horizontal 0 SWING button A TIMER MODE button B TIMER SET button C CLOCK ADJUST button D ...

Страница 5: ...ssed to change the time quickly in 10 minute increments 3 Press the CLOCK ADJUST button again This completes the time setting and starts the clock To Use the Remote Controller The Remote Controller must be pointed at remote control signal receiver to oper ate correctly Operating Range About 5 m When a signal is properly received by the receiver unit control panel some lamp will be flashed If no la...

Страница 6: ...ut 3 seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches that of the temperature setting the fan speed becomes slower Fan The fan runs at the low fan speed The fan will o...

Страница 7: ...ed the air conditioner will operate at very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before beginning full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatica...

Страница 8: ...e desired OFF time or ON time Set the time while the time display is flashing the flashing will continue for about 5 seconds button Press to advance the time button Press to reverse the time About 5 seconds later the entire display will reappear To Use the Program timer 1 Press the START STOP button if the unit is already operating proceed to step 2 The receiver unit control panel s OPERATION Indi...

Страница 9: ...ur 1 hour 30 minutes Set time During Cooling Dry operation When the SLEEP timer is set the temperature setting is auto matically raised 1 C every 1 hour When the temperature has been raised a total of 2 C the temperature setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting During Heating operation When the S...

Страница 10: ...he set temp under cooling mode and lower than set temp under heating mode Therefore the economy mode is able to save more energy than other normal mode 10 C HEAT OPERATION The room temperature can be maintained at 10 C by pressing the 10 C HEAT button so as to prevent the room temperature from falling too far To use 10 C HEAT OPERATION Press the 10 C HEAT button The OPERATION indicator lamp green ...

Страница 11: ...e The remote controller resets to signal code A when the batteries in the remote controller are replaced If you use a signal code other than signal code A reset the signal code after replacing the batteries If you do not know the air conditioner signal code setting try each of the signal codes until you find the code which operates the air conditioner CLEANING AND CARE When used for extended perio...

Страница 12: ...Automatic Defrosting operation When Heating operation is started fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the temperature setting the outdoor unit will stop and the in door unit will operate at very low fan speed If you wish to warm the room further set the temperature for a higher setting During Heating opera...

Страница 13: ...s on the heat pump princi ple absorbing heat from outdoor air and transferring that heat to indoor unit As a result the operating perform ance is reduced as outdoor air temperature drops If you feel that insufficient heating performance is being pro duced we recommend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room...

Страница 14: ...ut provided by your units and use the units in the way that best matches your family s lifestyle If you discover that 1 or more units delivers a low level of cooling or heating during simultaneous operation we recommend that you stop simultaneous operation of the multiple units Operation cannot be done in the following different op erating modes If the indoor unit is instructed to do an operating ...

Страница 15: ... ...

Страница 16: ......

Отзывы: