2 2  Electrical connections 

The  electrical  installation  must  be  conducted  in 

accordance with the prevailing regulations.
The electrical connections must only be made when all 

the other fitting operations have been completed (fixing, 

assembly, etc.).
The  heat  pump  must  be  supplied  with  power  by 

special  protected  leads  from  the  electric  panel 

via  2-pole  circuit  breakers  specially  dedicated  to  the 

heat pump : Curve D.
The electrical installation must necessarily be equipped 

with a 30mA differential protection.

 -Ensure  that  the  general  electrical  power  supply  has 

been cut off before starting any repair work.

 -It is essential to maintain the live-neutral polarity when 

making the electrical connections.

 -Tighten the cables using the cable glands to prevent 

the conductors from disconnecting accidentally.

 -Ensure  that  the  ground  wire  is  longer  to  prevent 

accidental disconnections.

 

"

Do  not  place  the  sensor  lines  and  the  sector 

supply  lines  in  parallel  in  order  to  avoid 

interferences due to voltage points in the sector 

supply 

• Connecting to regulation cards

 -Remove the corresponding connector and make the 

connection.

• Connecting to spring terminals :
Rigid wires

 -Strip away around 10 mm from the end of the wire.
 -Slide  the  wire  into  the  opening  provided  for  this 

purpose.

 -Push  the  spring  with  a  screwdriver  so  that  the  wire 

enters the cage.

 -Remove the screwdriver and then check that the wire 

is jammed in the cage by pulling on it.

Flexible wires

 -Use the ends and proceed as before.

2 2 1  Electrical connections on the control box side

• Make  the  connections  in  accordance  with  the 

diagram 

figure 7

.

 -Connect  the  interconnection  cable  between 

terminals 1, 2, 3 and 4 (earth) of the control box and  

the terminals 1, 2, 3 and  earth of the heat pump.

• DHW tank with electrical back-up heating (option)

 -Connect  the  distribution  valve  to  connector  

QX4, eath and N.

 -Connect  the  domestic  water  sensor  to  terminal  

BX1 and M.

 -Conect  the  DHW  back-up  to  terminals  17  (earth),  

18 and 19.

 -Connect  the  back-up  electrical  supply  to  terminals  

14, 15 and 16 (earth).

• Boiler connection :

 -Connect  the  distribution  valve  (deviation  boiler) 

to the termianls 11 (earth), 12 and 13.

 -Connect 

the 

boiler 

supply 

to 

terminals  

8, 9 and 10 (earth).

• Floor heating system

Heated floor thermal safety fuse.

 -The installer is responsible for connecting the heated 

floor’s  safety  system.  Thermal  safety  will  stop  the 

heat pump if the temperature in the floor is too high. 

The heated floor's safety system must cut the electrical 

supply of the heat pump with a relay.

• Contract with the power provider :

The  heat  pump’s  operation  can  be  controlled  to  suit 

special contracts (e.g. off-peak, day/night).
In  particular,  domestic  hot  water  (DHW)  at  Nominal 

temperature will be produced during the off-peak hours 

when electricity is cheaper.

 -Connect the "Power Provider” contact to input EX5.
 -Set the parameter (1620) to "Off-peak hours".

• 230V on input EX5 = "Peak hours" information activated 

(Basic  setting  /  Modification  possible  line  5989, 

menu Configuration).

• Power limitation or EJP (peak day removal) :

Power  limitation  is  intended  to  reduce  electrical 

consumption  when  this  is  too  high  compared  to  the 

contract with the power provider.

 -Connect  the  power  limiting  device  to  input  EX4,  the 

back-ups for the heat pump and the DHW stop in the 

event of over-consumption by the dwelling.

• 230  V  on  input  EX4  =  power  limitation  in  progress.  

(Basic  setting  /  Modification  possible  line  5987, 

menu Configuration). (Operating line 2920)

• External faults the heat pump :

Any  component  of  carryforward  of  information 

(thermostat,  pressure  switch,  etc.)  may  signal  an 

external problem and stop the heat pump.

 -Connect the external component to input EX6.

• 230  V  on  input  EX6  =  stoppage  of  heat  pump 

(the system displays Error 369).

Installation and operating manual "1395 - EN"

- 9 -

Control Box

Содержание UTW-SCBYA

Страница 1: ... professionals To be saved for future consultation FR EN IT NL DE Control Box UTW SCBYA Document n 1395 1 09 02 2010 Fujitsu General Euro GmbH Werftstrasse 20 40549 Düsseldorf Germany Subject to modifications without notice Non contractual document ...

Страница 2: ...Complies with Low voltage directive 73 23 CEE under standard EN 60335 1 Electromagnetic compatibility Diretive 89 336 CEE Installation and operating manual 1395 EN Control Box 2 ...

Страница 3: ...ng the slope of heating 14 Temperature control 14 Manual adjustment 14 Self adaptation 14 Parametering the setting 16 General 16 Setting parameters 16 List of function lines settings diagnosis status 16 Configuring the installation 28 Configuration 1 2 5 or 7 29 Hydraulic connections 29 Electrical connections 29 Parametering the setting 29 Special cases 29 Electrical wiring diagram 34 Troubleshoot...

Страница 4: ...nstallation and operating manual 1395 EN Control Box 4 References of heat pump Monobloc heat pump Control Box Model Output Code WPYA080LA 8 kW UTW SCBYA WPYA100LA 10 kW Optional equipment DHW kit UTW KDWXA for connecting a DHW tank with built in electrical backups Boiler connection kit UTW KBSXA for connecting a boiler to the heat pump Room thermostat UTW C55XA For correcting the ambient temperatu...

Страница 5: ... 4 Control box components Front view 1 2 3 4 5 6 Back view Side view Legend 1 Start stop switch 2 User interface 3 Interface and power card 4 Regulator 5 Terminal blocks 6 DHW power relay 1 4 Description Installation and operating manual 1395 EN 5 Control Box ...

Страница 6: ...heat pump program line 560 561 and 562 is set for nominal temperature from 0 00 to 5 00h and for reduced temperature for the rest of the day This optimizes electrical consumption while ensuring comfortable availability of hot water Setting for reduced temperature can be useful to prevent the DHW from switching on too often and for too long during the day The production of domestic hot water DHW is...

Страница 7: ...aging The sensor must be installed in the living room area on a very uncluttered wall 1 5 m above the floor Avoid direct sources of heat chimney flue television cooking hobs draughty areas ventilation door etc Air leaks in the seals in the constructions are often translated into cold air blowing through the electrical conduits Lag the electrical conduits if there is a cold draught on the back of t...

Страница 8: ...l back ups 230 V Connection to the DHW tank resistance 2 1 3 2 1 CL CL G M M B9 M BX1 CL CL QX4 N EX6 EX5 EX4 Outdoor sensor DHW sensor DHW distribution valve 5 Room thermostat ou Room control unit options External fault Tariffs day night peak times off peak times Power shedding or EJP peak day removal External component contact faults load shedder power meter If the control device does not provid...

Страница 9: ...option Connect the distribution valve to connector QX4 eath and N Connect the domestic water sensor to terminal BX1 and M Conect the DHW back up to terminals 17 earth 18 and 19 Connect the back up electrical supply to terminals 14 15 and 16 earth Boiler connection Connect the distribution valve deviation boiler to the termianls 11 earth 12 and 13 Connect the boiler supply to terminals 8 9 and 10 e...

Страница 10: ...ture To avoid this situation the sensor must be connected correctly Re initialise parameter 8703 commissioning level consumer diagnostic menu 2 4 Configuring room thermostat To configure the room thermostat and connect it to the appropriate heating zone Hold down the presence key for more than 3 seconds The room thermostat displays RU and a number flashes Turn the wheel to choose the zone 1 Hold d...

Страница 11: ... Installation and operating manual 1395 EN 11 Control Box ...

Страница 12: ...n figure 9 User interface of the control box Auto ESC OK RESET 0 4 8 12 16 20 24 1 2 3 4 5 6 7 8 9 figure 10 Room control unit option Auto ESC OK 0 4 8 12 16 20 24 1 2 3 4 5 7 12 8 6 figure 11 Room thermostat option C Auto 5 10 11 12 Installation and operating manual 1395 EN Control Box 12 ...

Страница 13: ...atic Constant comfort temperature Constant reduced temperature Stand by mode with anti frost protection Provided that the heat pump s electrical power supply is not interrupted 6 Information display Various data page 35 Reading error codes Information concerning maintenance special mode 7 Confirm OK Input into the selected menu Confirmation of the parameter settings Confirmation of the adjustment ...

Страница 14: ... temperature control parameter 721 modifies the initial temperature of all the curves without modification of the slope figure 13 The corrective actions in the case of any inconvenience are detailed in the table figure 14 3 2 3 Self adaptation When this function is active parameter 726 the temperature control is automatically adjusted it is therefore futile to modify the slope or the off set in th...

Страница 15: ... weather Curve slope line 720 Curve off set line 721 No correction No correction No correction No correction No correction OK OK OK OK OK OK Cold Cold Cold Cold Cold Hot Hot Hot Hot Hot Hot Cold No correction Corrective actions on the temperature control 90 80 70 60 50 40 30 C 100 C 20 20 10 1 0 75 1 75 0 5 0 25 1 25 10 0 2 1 5 2 25 2 5 Boiler connection application Heat pump application only Heat...

Страница 16: ...1 Hours 1 24 h Operator section Day month 2 Minutes 0 60 min Time prog heating circuit 1 Year 3 Press for 3 seconds End user Commissioning Engineer OEM Time of day and date Hours minutes 1 Operator section Day Month 2 Time prog heating circuit 1 Year 3 Start of summer time 4 01 01 31 12 End of summer time 5 Line Function Setting range or display Setting increment Basic setting Date and time 1 U Ho...

Страница 17: ... is fitted with a DHW tank Only with the DHW kit option 560 U Pre selection Day Week Mon Sun Mon Fri Sat Sun Monday Tuesday Mon Sun 561 U 1st phase On start 00 00 10 min 00 00 562 U 1st phase Off end 00 00 10 min 05 00 563 U 2nd phase On start 00 00 10 min 564 U 2nd phase Off end 00 00 10 min 565 U 3rd phase On start 00 00 10 min 566 U 3rd phase Off end 00 00 10 min 576 U Default values No Yes No ...

Страница 18: ...C 10 C 1 C 3 C This function enables you partially to offset the automatic summer winter switchover during the intermediate seasons Increasing the value delays the switchover to summer regime Decreasing the value advances the switchover to summer regime This function is only active in automatic mode 740 S Flow temp setpoint min for fan convectors 8 95 C 1 C 8 C 741 S Flow temp setpoint max 8 95 C ...

Страница 19: ...ops automatically after running for 25 days 856 I Floor curing day current 0 32 857 I Days complete current 0 32 900 S Operating mode changeover None Protection mode Reduced Comfort Automatic 1 Protection mode Operating mode at end of concrete slab drying period Please comply with the standards and instructions of the manufacturer of the building A good performance ofthisfunctionisonlypossible wit...

Страница 20: ...ode after having operated in heating mode and vice versa 918 S Summer comp start at OT 20 50 C 1 C 26 C The comfort setting 902 is increased in line with the outdoor temperature rising above this reading 919 S Summer comp end at OT 20 50 C 1 C 40 C Above this reading the comfort setting 902 is no longer affected by an increase in the outdoor temperature 920 S Summer comp setp increase 1 10 C 1 C 4...

Страница 21: ...cr hygro 1 20 C 1 C 10 C 948 S Flow setp incr start at r h 0 100 1 60 950 S Flow temp diff dewpoint 0 5 C 1 C 2 C 963 S With prim contr system pump No Yes No 969 S Operating mode changeover No Off Automatic Off 30 20 18 16 C C 25 35 908 909 923 924 Flow temperature setpoint Outside temperature Flow temperature setpoint with minimum limit Flow temperature setpoint without minimum limit figure 18 Li...

Страница 22: ...only authorised during off peak hours 1640 I Legionella function Off Periodic depending on the line setting 1641 Set day of the week depending on the line setting 1642 Off 1641 I Legionella funct periodically 1 to 7 1 day 7 1642 I Legionella funct weekday Monday Tuesday Saturday 1644 I Legionella funct time 00 00 23 50 If no value is entered no anti legionella cycle has been run 1645 I Legionella ...

Страница 23: ...on and 1 heating circuit Pre setting 7 Boiler connection 1 heating circuit and DHW tank Pre setting 3 4 6 8 to 12 Do not use for monobloc heat pump 5711 S Cooling circuit 1 Off 4 pipe system 2 pipe system Off 4 pipe system is not compatible with the heat pump Select 2 pipe system to activate cooling operation 5870 S Combi storage tank No Yes No 5987 S Cont type input EX4 Normally closed contact NC...

Страница 24: ...ult occurs error 370 On The heat pump uses the boiler connection when a fault occurs error 370 In the On position the energy costs can be onerous if the error is not eliminated 7142 S Emergency operating function type Manual Automatic Manual Manual Emergency mode is not active when a fault occurs Emergency mode OFF Automatic Emergency mode is active when a fault occurs Emergency mode ON In Automat...

Страница 25: ...28 350 C 0 7833 I Sensor temperature BX22 module 2 28 350 C 0 7841 I Contact status H1 Open Closed Open 7846 I Contact status H2 Open Closed Open 7855 I Contact status H3 Open Closed Open 7914 I Input EX4 0 230 V 0 7915 I Input EX5 0 230 V 0 7916 I Input EX6 0 230 V 0 State 8000 I State heating circuit 1 0 8003 I State DHW 0 8004 I State cooling circuit 1 0 8006 I State heat pump 0 8022 I State su...

Страница 26: ...50 C 8701 U Outside temp min Reset No Yes 50 50 C 8702 U Outside temp max Reset No Yes 50 50 C 8703 I Outside temp attenuated Reset No Yes 50 50 C This is the average of the outdoor temperature over a 24 hour period This value is used for automatic Summer Winter switchover line 730 8704 I Outside temp composite 50 50 C The composite outdoor temperature is a combination of the current outdoor tempe...

Страница 27: ...w temperature setpoint 0 140 C 0 8957 I Common flow setpoint refrigeration 0 140 C 9031 I Relay output QX1 Off On Off 9032 I Relay output QX2 Off On Off 9033 I Relay output QX3 Off On Off 9034 I Relay output QX4 Off On Off 9035 I Relay output QX5 Off On Off 9036 I Relay output QX6 Off On Off 9037 I Relay output QX7 Off On Off 9050 I Relay output QX21 module 1 Off On Off 9051 I Relay output QX22 mo...

Страница 28: ...700 Type of installation Page Pre setting 1 1 heating circuit 30 Pre setting 2 1 heating circuit and DHW tank 31 Pre setting 3 Do not use for monobloc heat pump Reserved only for 2 circuits installation Pre setting 4 Pre setting 5 Boiler connection and 1 heating circuit 32 Pre setting 6 Do not use for monobloc heat pump Reserved only for 2 circuits installation Pre setting 7 Boiler connection 1 he...

Страница 29: ...10 to 1661 Adjust the heating curve slope line 720 4 1 4 Special cases Please consult us regarding any other installation configuration DHW tank control with electrical back up requires the use of the DHW kit The management of a boiler is required to install a boiler connection kit 4 1 1 Hydraulic connections In the case of a mixed DHW tank Install the distribution valve on the heating circuit in ...

Страница 30: ...egulation Control Box R Radiators or fan convectors CA Room control unit or Room thermostat option SE Outdoor sensor SP Heated floor thermal safety fuse Overall hydraulic layout Overview of all the electrical connections See detailed instructions on page 28 Installation and operating manual 1395 EN Control Box 30 ...

Страница 31: ...lation pump CR Regulation Control Box KS DHW kit R Radiators or fan convectors CA Room control unit or Room thermostat option SE Outdoor sensor SP Heated floor thermal safety fuse SSa DHW sensor VD Distribution valve Overall hydraulic layout Overview of all the electrical connections Configuration 2 1 heating circuit and DHW tank Installation and operating manual 1395 EN 31 Control Box ...

Страница 32: ...alve CCI Heatingsystemcirculationpumpbuiltintotheboiler CC Heating circulation pump CR Regulation Control Box R Radiators or fan convectors CA Room control unit or Room thermostat option SE Outdoor sensor SDR Boiler connection valve flow sensor SP Heated floor thermal safety fuse TA Boiler supply of boiler unit VDI Distribution valve deviation boiler Ex boiler unit Ex boiler unit See detailed inst...

Страница 33: ...avity feed valve CCI Heatingsystemcirculationpumpbuiltintotheboiler CC Heating circulation pump CR Regulation Control Box R Radiators or fan convectors CA Room control unit or Room thermostat option KS DHW kit SE Outdoor sensor SDR Boiler connection valve flow sensor SSa DHW sensor SP Heated floor thermal safety fuse TA Boiler supply of boiler unit VD Distribution valve VDI Distribution valve devi...

Страница 34: ...ref H1 H3 X30 DO1 DO2M BX4 BX5 1 L 2 N 3 COM 4 5 6 7 8 N 9 L 10 11 12 L 13 N 14 L 15 N OUTDOOR UNIT BOILER CONNECT BOILER VALVE DHW BACK UP SUPPLY DHW BACK UP CONNECT 16 17 18 L 19 N Connections to regulator accessories and options see figure 8 page 8 Connections to terminals see figure 7 page 8 Start stop switch Installation and operating manual 1395 EN Control Box 34 ...

Страница 35: ...s 369 External fault safety component No 370 Heat pump error Refer to the service manual of the heat pump No 6 2 Information display Various data can be displayed by pressing the info button Depending on the type of unit configuration and operating state some of the info lines listed below may not appear Possible error messages from the error code list Possible service messages from the maintenanc...

Страница 36: ...ent than default values 1610 1612 3 Start a legionella cycle 1640 1647 4 Perform floor drying 850 857 7 2 Start up check list 7 2 1 Before starting up Sight checks Heat pump OK Non compliant Location and fittings condensate evacuation Compliance with distances from obstacles Hydraulic checks OK Non compliant Value Connection of pipes valves and pumps 1 circuit DHW Installation water volume expansi...

Страница 37: ...After a few minutes measurement of air temp delta Check condensation and evaporation pressure temperature After 15 mins of operation Primary water temp delta DHW priority switching of selection valve Operation of heating mixing valve boiler backup Control settings Room control see chapiter Configuring the room thermostat page 10 OK Non compliant Settings manipulations checks Setpoint display Expla...

Страница 38: ...kup 3700 OT switch on authoris addit gen 3705 swith off delay addit gen Miscellaneous 6046 input H2 function 9 configuration 6100 OT sensor correction configuration 6120 frost protection on off configuration 6205 reset settings configuration 6220 software version configuration 6711 reset heat pump error 7070 to 7183 maintenance maintenance 7700 to 7916 input output testing I O testing 8402 to 8457...

Страница 39: ...ation C Water input temperature C ΔT secondary C Evaporation temperature LP bar C Suction temperature C Overheating C Battery air input temperature C ΔT evaporation C Battery air output temperature C ΔT battery C Hydraulic system of hydraulic unit Secondary system Low temp heating floor Circulator brand Type LT Radiators Circulator brand Type fan coils Domestic hot water tank type Circulator brand...

Страница 40: ...is appliance also conforms to Regulation 842 2006 of the european parliament on certain fluorinated greenhouse gases The standards relating to the product and the testing methods used Air conditioners refrigeration units and heat pumps with compressor driven by electric motor for heating and refrigeration EN 14511 1 14511 2 14511 3 and 14511 4 To standard XP ENV 12102 Air conditioners heat pumps a...

Отзывы: