After the ILOM reset or the power cable removal
and insertion, when the server powered on,
Solaris OS startup at the
ok
prompt of OBP
(OpenBoot PROM) using the
boot
command
may fail.
Error output example:
{0} ok
boot
ERROR: All device paths in
boot-device have failed. (*)
{0} ok
It cannot refer to the device paths that
configured in the OBP environmental variable
boot-device and fails to start Solaris OS.
Note - Fixed in System Firmware 7.2.2.e or
later.
After the ILOM reset or the power cable removal
and insertion, when you power on the server,
check the OBP environmental variable.
Especially, in case the OBP environmental
variable
use-nvramrc?
has been set to
true
, it
is necessary in advance of starting the OS to see
the
ok
prompt and check that
use-nvramrc?
has been set to
true
and then execute the
boot
command.
Confirmation example:
{0} ok
printenv use-nvramrc?
use-nvramrc? = true
{0} ok
6694693
ILOM allows only two privileges: Administrator
and Operator. Therefore, the following text
about the ALOM CMT
userperm
command in
the manual is inappropriate.
If one of [c], [u], [a], and [r] is set, Administrator
authority will be in effect. If nothing is specified,
Operator authority will be in effect.
<
Integrated Lights Out Manager 2.0 Supplement
>
userperm [username] [c][u][a][r]
Note - Fixed in System Firmware 7.2.2.e or
later.
None.
6579390
After disabling a DIMM, the OpenBoot PROM
banner does not show a decrease in the amount
of memory.
Note - Fixed in System Firmware 7.2.2.e or
later.
If you manually disable any CPU or memory
resource with the ASR commands while the host
is powered on, you must power cycle the host to
complete the disabling of the resource.
After the power cycle, the resource will be
disabled, and the proper information will be
displayed in the banner.
6656116
If the DIMM module fails, the MCU will be
disconnected, and an error message might be
output to the console.
For an example of the message, see
Be Disconnected in DIMM Module Failure (CR
6656116)” on page 69
.
Note - Fixed in System Firmware 7.1.8.a or
later.
Identify and replace the faulty DIMM module.
TABLE A-3
Fixed ILOM Issues
(Continued)
CR ID
Description
Workaround
Содержание SPARC Enterprise T5440 Server
Страница 4: ......
Страница 18: ...8 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Страница 38: ...28 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Страница 58: ...48 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Страница 66: ...56 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Страница 92: ...82 SPARC Enterprise T5440 Server Product Notes December 2010 ...