Chapter 3
Known Issues
39
6835866
6857524
6858176
The value of power consumption shown by
/SYS/VPS (/SYS/VPS value) may exceed the
threshold value. At this time, an event log as
shown below will be collected.
Event log example:
4368 Mon Jun 29 23:53:39 2009
IPMI Log major
ID = e1f : 06/29/2009 : 23:53:39 :
Power Unit : /SYS/VPS : Upper
Critical going high : reading
1480.90 > threshold 1215.40 Watts
And when the power consumption value
(/SYS/VPS value) has come back to under the
threshold, it may display an abnormal value.
Abnormal value display example:
4369 Mon Jun 29 23:54:28 2009
IPMI Log minor
ID = e20 : 06/29/2009 : 23:54:28 :
Power Unit : /SYS/VPS : Upper
Critical going low : reading 0 <
threshold 1215.40 Watts
None.
The value of power consumption shown by
/SYS/VPS is given as an indication.
For the right value of power consumption, see
/SP/powermgmt/actual_power.
Therefore, the collected event log can be safely
ignored.
6952927
In the environment where applied System
Firmware 7.2.8 or later, when you restore the
ILOM setting and downgrade the firmware
version to earlier than 7.2.8, the log output may
be limited to part of the past ILOM event log.
For details, see
Firmware, the Log Output May Be Limited to
Part of the Past ILOM Event Log (CR 6952927)”
on page 44
None.
The newly generated ILOM event log is
normally collected.
TABLE 3-4
ILOM Issues
(Continued)
CR ID
Description
Workaround
Содержание SPARC Enterprise T5440 Server
Страница 4: ......
Страница 18: ...8 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Страница 38: ...28 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Страница 58: ...48 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Страница 66: ...56 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Страница 92: ...82 SPARC Enterprise T5440 Server Product Notes December 2010 ...