U41182-J-Z126-1-74
29
Switching on and off
Switching the S120 on and off from a remote system
5.6 Switching the S120 on and off from a remote system
Figure 16: Switching the S120 on and off from a remote system
Switching on and off can be carried out from a remote system using a modem/DCU. In
addition, automatic switching on/off of the S120 must be configured as part of the starting
and shutting down procedure for the SKP (see page 25). The SKP switches during startup
the S120 on. After the IMPL, the BS2000 system is started using the POWER ON IPL
function of the SVP.
Information on operating the DCU can be found in the data sheet “8323 Data Communi-
cation Unit” [5].
V.24
on/off facility
internal LAN
I/O channel
SKP
LAN
Console
Telephone network
Mod
e
m
DCU
8323
or
ATOP
DCU
8323
SVP
S120
Mo
de
m
COM1
Remote operator terminal