U41182-J-Z126-1-74
21
Switching on and off
Switching the S120 on and off using the control panel
3. You can also terminate the SINIX system using the on/off button on the SKP.
When you switch off the SKP, take note of the following:
If the SKP is switched off , it sends the command /shutdown or a self-defined /run
xxxx command (default value) to any running BS2000 system before it switches
itself off after a certain wait time has expired.
You can define the shutdown command and the length of the wait period using the
sysadm forms.
Information on operation of the FMLI interfaces can be found in the “SINIX-2000
V7.5/V8.0” manual [1].
Ê
Select or open a SINIX screen
Ê
Login:
root
or
sysadm
Ê
Enter password
Ê
For login with root: enter
sysadm
The SINIX system administration window is displayed.
Figure 9: SINIX system administration window
Ê
Select the menu item “sinix_2000” on the UNIX System V, Administration menu.
Ê
Select the menu item “up_down” on the SINIX-2000 system administration menu.
!