TX300 S3
Options Guide
77
Converting from the floorstand model to the rack model
Figure 66: Removing the bar
Ê
Remove the three screws (1) on the bar.
Ê
Push the bar to the rear (2) until the hooks disengage.
Ê
Remove the bar (3).
I
The bar is no longer required.
The drive cage for the accessible drives is constructed in such a way that the
accessible drives and the operating panel module can be taken out simply,
turned through 90° to the left, and then be reinstalled.
Ê
Remove the ventilation duct over the system fans (see
page 32
).
Ê
Remove the dummy covers from the drive cage (
figure 50 on page 60
).
Ê
Unplug the cables from the system board or the accessible drives and
remove the drives from the drive cage.
Ê
Pull the operating panel module forward out of its mounting location until you
can pull the I2C cable, the ribbon cable and USB cable out of the operating
panel module. Remove the three cables.
Ê
Remove the operating panel module.
Ê
Turn the operating panel module through 90° to the left.
Hook
1
1
1
3
2