TX1320 M1
Upgrade and Maintenance Manual
85
Basic software procedures
Ê
After completion of the flash process, remove the USB stick and restart the
server.
iRMC recovery procedure
I
For the Japanese market, follow the instructions provided separately.
Ê
Prepare a USB stick including the bootable iRMC firmware update image.
Ê
Ensure that the server has been shut down and disconnected from the
mains as described in section
"Shutting down the server" on page 52
.
Ê
Connect the USB stick to the USB port.
I
Ensure that only the USB device with the iRMC firmware is connected
to the USB port. Remove all other USB devices temporarily.
Ê
Connect the server to the mains while pushing the ID button on the front
panel. Ask a second person to help you if necessary.
Ê
Ensure that the Global Error indicator and the ID indicator are flashing to
indicate that the server is entering the iRMC recovery state.
Ê
Press the Power On / Off button. The system starts the POST process.
I
In iRMC recovery mode, the “FUJITSU” logo does not show up.
Ê
The system will detect the USB stick.
I
If the BIOS cannot identify the USB stick, the pop-up message
Failed to boot for Emergency flash. Please Reset now
.
will show up in the center of the screen.
Ê
Choose the
Recovery_L
option from the update tool menu to start the iRMC
update process.
V
CAUTION!
Do not interrupt the iRMC upgrade process after it has started. If the
process is interrupted, the iRMC BIOS may be permanently
corrupted.
I
If the iRMC does not work after flashing, disconnect the system from
the mains and reconnect it again.
Ê
Shut down the server by pressing the power On / Off button.
Ê
Disconnect the server from the mains to exit the iRMC recovery state.
Содержание PRIMERGY TX1320 M1
Страница 18: ...Upgrade and Maintenance Manual TX1320 M1 Contents ...
Страница 42: ...42 Upgrade and Maintenance Manual TX1320 M1 Important information ...
Страница 106: ...106 Upgrade and Maintenance Manual TX1320 M1 Basic software procedures ...
Страница 150: ...150 Upgrade and Maintenance Manual TX1320 M1 Hard disk drives solid state drives ...
Страница 280: ...280 Upgrade and Maintenance Manual TX1320 M1 Front panel ...
Страница 320: ...320 Upgrade and Maintenance Manual TX1320 M1 Cables Figure 200 Cabling with extension box ...