Hard disk drives / solid state drives
7.2.3.2
Removing a 2.5-inch HDD / SSD module
Figure 39: Disconnecting a 2.5-inch HDD / SSD module
Ê
Pinch the green locking clips (1) and fully open the locking lever (2).
I
Thereby, the HDD / SSD module is pushed out of its drive bay by
about 1 cm and disconnected from the SAS / SATA backplane.
Ê
Wait about 30 seconds to allow the hard disk drive to spin down.
I
This is not necessary when removing a solid state drive.
/