140
Upgrade and Maintenance Manual
TX1320
M1
Hard disk drives / solid state drives
7.4
Replacing SAS / SATA backplane
7.4.1
Replacing 2.5- inch SAS / SATA backplane
7.4.1.1
Preliminary steps
I
The 2.5-inch HDD SAS / SATA backplane is mounted on the drive cage.
It is not necessary to remove the drive cage before replacing the
SAS / SATA backplane
Before replacing a 2.5-inch HDD SAS / SATA backplane, perform the following
steps:
Ê
Disable BitLocker functionality as described in section
"Disabling BitLocker
functionality" on page 73
.
Ê
Shut down the defective server as described in section
"Shutting down the
server" on page 52
.
Ê
Disconnect the AC power cord from the system.
Ê
Disengage all HDD modules from the server as described in section
"Removing 2.5-inch HDD / SSD modules" on page 122
.
I
You need not to remove the 2.5-inch HDD / SSD completely but if you
do so please follow the next caution.
V
CAUTION!
Ensure that all hard disk drives are uniquely identified so that you can
reinsert them into their original bays after replacing the HDD
backplane.
Ê
Remove the server cover as described in section
"Opening the server" on
page 55
.
Field Replaceable Unit
(FRU)
Hardware: 10 minutes
Tools:
Preliminary and concluding steps: tool-less
Replacing the SAS backplane: Phillips PH2 / (+) No. 2 screw driver
Содержание PRIMERGY TX1320 M1
Страница 18: ...Upgrade and Maintenance Manual TX1320 M1 Contents ...
Страница 42: ...42 Upgrade and Maintenance Manual TX1320 M1 Important information ...
Страница 106: ...106 Upgrade and Maintenance Manual TX1320 M1 Basic software procedures ...
Страница 150: ...150 Upgrade and Maintenance Manual TX1320 M1 Hard disk drives solid state drives ...
Страница 280: ...280 Upgrade and Maintenance Manual TX1320 M1 Front panel ...
Страница 320: ...320 Upgrade and Maintenance Manual TX1320 M1 Cables Figure 200 Cabling with extension box ...