52
Operating Manual
RX4770 M2
Hardware installation
5.4
Connecting the server to the mains
V
CAUTION!
The server is automatically set to a mains voltage in the range
100 - 240 V or 200 – 240 V (depending on PSU model used). You may
only operate the server if its rated voltage range corresponds to the local
mains voltage.
5.4.1
Installation requirements
The power subsystem consists of:
– Power supply modules (PSU)
– A power distribution board (PDB)
The power supply subsystem can support up to 4 PSUs which all connect to the
PDB. The total system is rated 100 - 240 V, 24 - 16 A, 50 - 60 Hz or 200 – 240 V,
20 A (depending on PSU model used, refer to your system’s rating plate).The
minimum system configuration requires installation of at least two PSUs. The
PSU is considered hot-swappable. The system can be configured to support
*True AC redundancy or non-AC redundancy.
I
*True AC redundancy is recommended for systems used for critical
business applications. This will result in the system to continue operation
during a power failure as the redundant part of the subsystem is plugged
into a separate AC source (e.g. uninterruptable power supply (UPS)).
I
Refer to tables below for maximum DC loading for both AC redundant
and AC non redundant configurations.
Содержание PRIMERGY RX4770 M2
Страница 1: ...Operating Manual English FUJITSU Server PRIMERGY RX4770 M2 Operating Manual Edition April 2015 ...
Страница 6: ...Operating Manual RX4770 M2 ...
Страница 10: ...Operating Manual RX4770 M2 Contents ...
Страница 14: ...14 Operating Manual RX4770 M2 Preface ...
Страница 28: ...28 Operating Manual RX4770 M2 Functional overview ...
Страница 42: ...42 Operating Manual RX4770 M2 Important information ...
Страница 47: ...RX4770 M2 Operating Manual 47 Hardware installation Figure 2 Mechanical requirements 735 770 mm 100 mm 1 6mm ...
Страница 78: ...78 Operating Manual RX4770 M2 Property and data protection ...
Страница 84: ...84 Operating Manual RX4770 M2 Troubleshooting and tips ...