RX300 S3
Operating manual
41
Hardware Installation
Installing/Removing the Server into/from the Rack
4.2.2
Mounting into 3rd-Party Racks
For mounting the server into the 3rd-Party Rack the following parts are
necessary:
–
one left and one right telescopic rail (assembled)
–
M5-10 screws including plugwashers
I
–
Alternatively, M5x10 screws with separate plugwashers can be
used. In this case, two plugwashers must be pre-mounted at the
support uprights and the support bracket.
–
In this section instructions and figures include the vario rail.
Ê
Take the manual of the rack manufacturer regarding the mechanical instal-
lation and/or the climatic conditions to assistance.
V
CAUTION!
With the installation in 3rd-Party Rack it is to be made certain that the
air flow is ensured from the front to the rear in the rack.
Ê
Mount the necessary manufacturer original parts (like support bracket or
cable management).
I
Sometimes a number of parts of the delivered mounting kit cannot be
used because original parts of the 3rd-Party Rack are to be used.
Ê
Remove the outermost telescopic rail as described on
).
Rack with clearance depth 735 mm
For rack systems with clearance depth 735 mm an adjustment of the delivered
rails is not necessary.
Ê
Mount the telescopic rails in the 3rd-Party Rack as described in
“Mounting into the PRIMECENTER/DataCenter Rack” on page 38
.
Ê
Mount the server (see
section “Installing the Server” on page 42
) and route
the cables as described in the original manual of the Rack.