CAUTION
▶
Only remove an HDD module during operation if the drive is not
currently being accessed. Observe the indicators on the
corresponding HDD module, see
SSD / PCIe SSD / EDSFF SSD modules" on page 557
.
▶
An HDD module can be replaced while the system is in operation.
RAID configuration with a RAID controller:
●
Modular Host Bus Adapter with "Integrated RAID" (IR). RAID
levels 0 and 1 are supported for internal HDD configurations.
●
Modular RAID 0/1 controller with "MegaRAID functionality"
(integrated MegaRAID). RAID levels 0, 1, 10, 5 and 50 are
supported for internal HDD configurations.
●
Modular RAID 5/6 controller with "MegaRAID functionality"
(MegaRAID). RAID levels 0, 1, 10, 5, 50, 6 and 60 are supported
for internal HDD configurations. As an option, a flash backup unit
(FBU) can save the memory content even if the power fails.
Cache memory size of up to 8 GB is available.
▶
An HDD module can be replaced while the system is in operation.
RAID configuration without a RAID controller:
Please follow the instruction of each software e.g. VSAN, Storage
Spaces, and Storage Spaces Direct, provided separately to use the
software RAID function of OS or Hypervisor.
▶
All HDD modules (drives) must be uniquely identified so that they
can be reinstalled in their original bays later. If this is not done,
existing data can be lost.
Preliminary steps
▶
"Locating the defective server" on page 49
▶
"Removing the front cover with lock" on page 52
.
▶
"Locating the defective component" on page 50
Hard disk drive (HDD) / solid state disk (SSD)
RX2540 M6
Upgrade and Maintenance Manual
151
Содержание PRIMERGY RX2540 M6
Страница 8: ...Upgrade and Maintenance Manual RX2540 M6 ...
Страница 34: ...Before you start 34 Upgrade and Maintenance Manual RX2540 M6 ...
Страница 86: ...Basic hardware procedures 86 Upgrade and Maintenance Manual RX2540 M6 ...
Страница 120: ...Basic software procedures 120 Upgrade and Maintenance Manual RX2540 M6 ...
Страница 232: ...Fans 232 Upgrade and Maintenance Manual RX2540 M6 ...
Страница 328: ...Expansion cards and backup units 328 Upgrade and Maintenance Manual RX2540 M6 ...
Страница 366: ...Processor CPU 366 Upgrade and Maintenance Manual RX2540 M6 ...
Страница 462: ...Front panel 462 Upgrade and Maintenance Manual RX2540 M6 ...
Страница 570: ...Appendix A 570 Upgrade and Maintenance Manual RX2540 M6 ...
Страница 572: ...FUJITSU Server PRIMERGY RX2540 M6 System Cabling Overview System Cabling Overview English Cable Plan for June 2021 ...
Страница 581: ...10 RX2540 M6 Basic Serial Cable Plan System Board D3891 A B Rear Serial CA05950 2142 Rear Serial ...
Страница 582: ...11 RX2540 M6 Basic LTO 16x2 5 Cable Plan System Board D3891 A B PWR 6 LTO CA05950 2144 MLC1 MLC2 C0 C1 Route via CPU2 ...
Страница 584: ...13 RX2540 M6 Basic OOB 10x3 5 Cable Plan System Board D3891 A B SMB 1 10x 3 5 HDD Backplane SMB 1 CA05950 2105 SB BP ...
Страница 585: ...14 RX2540 M6 Basic OOB 12x3 5 Cable Plan System Board D3891 A B SMB1 12x 3 5 HDD Backplane SMB 1 CA05950 2105 SB BP ...
Страница 593: ...22 RX2540 M6 Power 10x3 5 Cable Plan CA05950 2112 System Board D3891 A B PWR 2 10x3 5 HDD Backplane PWR 1 ...
Страница 594: ...23 RX2540 M6 Power 12x3 5 Cable Plan CA05950 2112 System Board D3891 A B PWR 2 12x3 5 HDD Backplane PWR 1 ...
Страница 600: ...29 RX2540 M6 Power Rear 4x2 5 Cable Plan System Board D3891 A B PWR 1 4x2 5 rear HDD Backplane CA05950 2136 PWR 9 ...
Страница 601: ...30 RX2540 M6 Power Rear 2x2 5 Cable Plan System Board D3891 A B PWR 1 2x2 5 rear HDD Backplane CA05950 2137 PWR 10 ...
Страница 602: ...31 RX2540 M6 Power Internal RAID Riser Cable Plan CA05950 2110 System Board D3891 A B PWR 1 Internal RAID Riser PWR 1 ...
Страница 667: ...96 RX2540 M6 Data Dual microSD 64GB Enterprise Cable Plan Dual microSD 64GB Enterprise A B ROC CON2 Y4018 V8 ...
Страница 672: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT June 2021 ...