RX2530 M1
Upgrade and Maintenance Manual
93
Basic software procedures
may have to log on to the server beforehand. The status of the
component will then be reset to
ok
. To see the new status you must
refresh the
Driver Monitor
view with
Refresh
.
I
For detailed information on how to view and sort the SEL using
ServerView Operations Manager, refer to the "ServerView Operations
Manager - Server Management" user guide.
Viewing the SEL using the iRMC web frontend
Ê
Enter the ServerView iRMC web frontend.
Ê
Select the
Event Log
and choose the
Internal Event Log
submenu.
Ê
Under
Internal Event Log Content
the SEL is being displayed. In order to filter
the list, select the check boxes next to the desired event types and press
Apply
for the changes to take effect.
I
For detailed information on iRMC settings, refer to the "Integrated
Remote Management Controller" user guide.
5.2.12.2 Clearing the SEL
You can clear the System Event Log (SEL) using the ServerView iRMC web
frontend:
Ê
Enter the ServerView iRMC web frontend.
Ê
Select the
Event Log
and choose the
Internal Event Log
submenu.
Ê
Under
Internal Event Log Information
click
Clear Internal Event Log
to clear the
SEL.
I
For detailed information on iRMC settings, refer to the "Integrated
Remote Management Controller" user guide.
5.2.13 Updating the NIC configuration file in a Linux
environment
In order to prevent errors caused by changing network device names (
eth<x>
),
it is recommended to store the MAC address (hardware address) of a network
interface card in the related NIC configuration file of the Linux OS.
When replacing a network controller or the system board with onboard LAN
controllers in a server running Linux OS, the MAC address will change but not
automatically be updated in the definition file.
Содержание PRIMERGY RX2530 M1
Страница 20: ...Upgrade and Maintenance Manual RX2530 M1 Contents ...
Страница 70: ...70 Upgrade and Maintenance Manual RX2530 M1 Basic hardware procedures ...
Страница 102: ...102 Upgrade and Maintenance Manual RX2530 M1 Basic software procedures ...
Страница 238: ...238 Upgrade and Maintenance Manual RX2530 M1 Main memory ...
Страница 240: ...240 Upgrade and Maintenance Manual RX2530 M1 Processors 11 1 Basic information Figure 162 CPU slots CPU 2 CPU 1 ...
Страница 260: ...260 Upgrade and Maintenance Manual RX2530 M1 Processors ...
Страница 272: ...272 Upgrade and Maintenance Manual RX2530 M1 Optical disk drive ...
Страница 290: ...290 Upgrade and Maintenance Manual RX2530 M1 Front panel ...
Страница 336: ...336 Upgrade and Maintenance Manual RX2530 M1 System board and components ...
Страница 352: ...352 Upgrade and Maintenance Manual RX2530 M1 Cables ...