136
Upgrade and Maintenance Manual
RX2530
M1
Hard disk drives / solid state drives
7.2.9
Replacing the 10 x 2.5-inch HDD backplane
7.2.9.1
Preliminary steps
Ê
"Locating the defective server" on page 45
Ê
"Shutting down the server" on page 48
Ê
"Disconnecting the server from the mains" on page 49
Ê
"Getting access to the component" on page 49
Ê
Release all HDD/SSD modules and pull them out a few centimeters, see
section
"Removing 2.5-inch HDD/SSD modules" on page 126
I
The HDD/SSD modules need not to be removed completely. But if
you want to remove them nevertheless, check if all HDD/SSD
modules are uniquely identified so that you can reinsert them into
their original bays.
Ê
If configuration with PCIe switch, disconnect the four SAS cables from the
HDD backplane.
Figure 59: Example configuration with PCIe switch
Field Replaceable Unit
(FRU)
Hardware: 15 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver (for removing/installing SAS
expander board)
Содержание PRIMERGY RX2530 M1
Страница 20: ...Upgrade and Maintenance Manual RX2530 M1 Contents ...
Страница 70: ...70 Upgrade and Maintenance Manual RX2530 M1 Basic hardware procedures ...
Страница 102: ...102 Upgrade and Maintenance Manual RX2530 M1 Basic software procedures ...
Страница 238: ...238 Upgrade and Maintenance Manual RX2530 M1 Main memory ...
Страница 240: ...240 Upgrade and Maintenance Manual RX2530 M1 Processors 11 1 Basic information Figure 162 CPU slots CPU 2 CPU 1 ...
Страница 260: ...260 Upgrade and Maintenance Manual RX2530 M1 Processors ...
Страница 272: ...272 Upgrade and Maintenance Manual RX2530 M1 Optical disk drive ...
Страница 290: ...290 Upgrade and Maintenance Manual RX2530 M1 Front panel ...
Страница 336: ...336 Upgrade and Maintenance Manual RX2530 M1 System board and components ...
Страница 352: ...352 Upgrade and Maintenance Manual RX2530 M1 Cables ...