RX2530 M1
Upgrade and Maintenance Manual
127
Hard disk drives / solid state drives
7.2.6.2
Removing a 2.5-inch HDD/SSD module
Ê
Pinch the green locking clips and open the locking lever (see figure
48
).
Ê
Pull the HDD/SSD module out a few centimeters.
Ê
Wait about 30 seconds to allow the hard disk drive to spin down.
I
This is not necessary when removing a solid state drive.
I
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the hard disk drive to come
to a stop.
Ê
Pull the HDD/SSD module completely out of its bay.
7.2.6.3
Installing a 2.5-inch HDD/SSD dummy module
V
CAUTION!
If the removed HDD/SSD module is not replaced immediately, always
replace a dummy module into the unused HDD/SSD bay to comply with
applicable EMC regulations and satisfy cooling requirements.
Figure 50: Installing a 2.5-inch dummy module
Ê
Push the dummy module into the empty bay until it engages.
7.2.6.4
Concluding steps
No steps needed.
Содержание PRIMERGY RX2530 M1
Страница 20: ...Upgrade and Maintenance Manual RX2530 M1 Contents ...
Страница 70: ...70 Upgrade and Maintenance Manual RX2530 M1 Basic hardware procedures ...
Страница 102: ...102 Upgrade and Maintenance Manual RX2530 M1 Basic software procedures ...
Страница 238: ...238 Upgrade and Maintenance Manual RX2530 M1 Main memory ...
Страница 240: ...240 Upgrade and Maintenance Manual RX2530 M1 Processors 11 1 Basic information Figure 162 CPU slots CPU 2 CPU 1 ...
Страница 260: ...260 Upgrade and Maintenance Manual RX2530 M1 Processors ...
Страница 272: ...272 Upgrade and Maintenance Manual RX2530 M1 Optical disk drive ...
Страница 290: ...290 Upgrade and Maintenance Manual RX2530 M1 Front panel ...
Страница 336: ...336 Upgrade and Maintenance Manual RX2530 M1 System board and components ...
Страница 352: ...352 Upgrade and Maintenance Manual RX2530 M1 Cables ...