RX2530 M1
Upgrade and Maintenance Manual
361
Appendix
The LEDs have the following meaning:
LED Indicator
Meaning
A - Identification blue on
server has been highlighted using iRMC
web frontend, ServerView Operations
Manager or the ID button on the front
panel for easy identification
blue flashing
local monitor off
B - CSS
(Customer Self
Service)
off
no error (CSS component)
orange on
indicates a prefailure (CSS component)
orange flashing indicates a failure (CSS component)
C - GEL
(Global Error
LED)
off
no error (non CSS component)
orange on
indicates a prefailure (non CSS
component)
orange flashing indicates a failure of a non CSS
component.
Reasons for a failure may be:
– over temperature measured by one of
the sensors
– sensor is defective
– CPU error
– software detected an error
F - PCI card
off
PCI card okay
orange on
PCI card failure (PCI card installed on riser
card)
G - CPU
off
CPU okay
orange on
CPU failure
H - Memory
off
memory module running
orange on
memory module failure
I - iRMC
off
iRMC S4 inactive
green flashing
iRMC S4 okay
K - System fan
off
system fan running
orange on
system fan failure
Содержание PRIMERGY RX2530 M1
Страница 20: ...Upgrade and Maintenance Manual RX2530 M1 Contents ...
Страница 70: ...70 Upgrade and Maintenance Manual RX2530 M1 Basic hardware procedures ...
Страница 102: ...102 Upgrade and Maintenance Manual RX2530 M1 Basic software procedures ...
Страница 238: ...238 Upgrade and Maintenance Manual RX2530 M1 Main memory ...
Страница 240: ...240 Upgrade and Maintenance Manual RX2530 M1 Processors 11 1 Basic information Figure 162 CPU slots CPU 2 CPU 1 ...
Страница 260: ...260 Upgrade and Maintenance Manual RX2530 M1 Processors ...
Страница 272: ...272 Upgrade and Maintenance Manual RX2530 M1 Optical disk drive ...
Страница 290: ...290 Upgrade and Maintenance Manual RX2530 M1 Front panel ...
Страница 336: ...336 Upgrade and Maintenance Manual RX2530 M1 System board and components ...
Страница 352: ...352 Upgrade and Maintenance Manual RX2530 M1 Cables ...