64
LED display specification list
The LED combinations are as follows. For LED details, refer to "7 Troubleshooting" (
*: The LED is not turned off until cleaning has normally completed (even if the server's power is
turned off, the LED is not turned off).
Two-color
LED
Segment
LED
One-color
LED
Status
Off
Off
Off
PowerOff: Power is not supplied to this product.
On (green)
–
Off
PowerOn (No cartridge): Power is supplied and a data cartridge can
be inserted manually.
On (green)
Off
Off
Ready: Power is supplied and a data cartridge is recognized by the
sensor. When the data cartridge has been loaded, this product can be
used.
Blinking
(green)
Off
Off
Running: This product is loading/unloading, unwinding the data car-
tridge, or writing/reading data on the data cartridge.
Blinking
(green)
C
Blinking
Cleaning
On (green)
P
Off
A write-protected cartridge or LTO2 (Read Only) cartridge was
loaded.
Blinking
(amber)
F
Blinking
Updating the firmware.
Blinking
(amber)
C
On
Cleaning request (*): Needs cleaning.
Blinking
(amber)
1
Off
The temperature value is abnormal.
Blinking
(amber)
2
Off
The voltage value is abnormal.
Blinking
(amber)
3
Off
The firmware update failed.
Blinking
(amber)
4
Off
A drive hardware error was detected.
Blinking
(amber)
5
Off
A hardware abnormality was detected.
Blinking
(amber)
6
Off
The data cartridge is abnormal.
Blinking
(amber)
7
Off
Incompatible cartridge inserted:
A data cartridge whose format was incompatible (LTO1) was inserted.
Blinking
(amber)
8
Off
Interface error
Blinking
(amber)
A
Off
The data on the data cartridge memory is abnormal.
Blinking
(amber)
c
(lower-
case)
Off
An unusable cleaning cartridge was inserted.
Blinking
(amber)
L
Off
An error occurred when the data cartridge was loaded.
Blinking
(amber)
U
Off
An error occurred when the data cartridge was unloaded.
Off
L
On
The Eject button was pressed while application software was running.