background image

50

Options Guide

 Econel200 

S2

Installing the memory air duct

Completion

10.2

Installing the memory air duct

Figure 28: Installing the traverse with the memory air duct

Ê

Insert carefully the traverse with the memory air duct.

Ê

Hook the traverse at the left side (see circles).

Ê

Press on the traverse at the right side (see arrow) until the locking bar 
engages.

Содержание PRIMERGY Econel 200 S2

Страница 1: ...l 200 S2 Server Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 Munich e mail email manuals fujitsu siemens com Tel 089 61001 155 Fax 49 700 372 00000 Econel200 S2 Sprachen En Edition January 2007 ...

Страница 2: ...according to DIN EN ISO 9001 2000 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft für Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2007 Fujitsu Siemens Computers Gmb...

Страница 3: ...4 1 Opening the server 17 4 2 Removing the processor fan 2 18 4 3 Removing the system fan 19 4 4 Removing the memory air duct 21 4 5 Removing the processor fan 1 22 5 Processors 25 5 1 Installing a second processor 25 6 Main memory 29 6 1 Slot population rules 29 6 2 Installing removing main memory 30 7 Accessible drives 33 7 1 Installing an accessible drive 33 7 2 Installing the 5 inch multibay 3...

Страница 4: ...rds in PCI slots 45 9 1 Installing an expansion board 45 10 Completion 49 10 1 Installing the processor fan 1 49 10 2 Installing the memory air duct 50 10 3 Installing the system fan 51 10 4 Installing the processor fan 2 52 10 5 Closing the server 53 11 Appendix 55 11 1 Cabling 55 Related publications 59 Index 61 ...

Страница 5: ... by clicking on industry standard servers Concept and target groups This Options Guide shows you how you can expand and upgrade the server The activities described in this manual may only be performed by technical specialists Additional documentation about the server The PRIMERGY Econel 200 S2 documentation comprises the following additional manuals Safety notes and other important information pri...

Страница 6: ...so available on the ServerBooks DVD I If you need a backup of the ServerBooks DVD send the details of your server via email address Reklamat PC LOG fujitsu siemens com LSI SATA Software RAID User s Guide PDF file available on the ServerBooks DVD Further sources of information Manual on the monitor Manual on ServerView Server Management Manual on RemoteView Remote Server Maintenance Documentation o...

Страница 7: ... 4200F Fully Buffered DIMM memory modules You find further information on the main memory in the Technical Manual for the system board D2530 Additional accessible drives Three free 5 25 inch bays are available for additional accessible drives DVD ROM CD RW DVD DVD RW or tape backup drive The lowest bay can be equipped with a 5 inch multibay In this multibay a 1 44 MB floppy disk drive and a slimli...

Страница 8: ...are programs quotation marks indicate names of chapters and terms that are being emphasized Ê describes activities that must be performed in the order shown V CAUTION Pay particular attention to texts marked with this symbol Failure to observe this warning may endanger your life destroy the system or lead to the loss of data I indicates additional information notes and tips Table 1 Notational conv...

Страница 9: ...he safety instructions in the chapter Safety notes on page 11 et seq Ê Ensure that all required manuals see Additional documentation about the server on page 5 are available printing out the PDF files if necessary You will definitely need the Operating Manual for the server and the Technical Manual for the system board Ê Shut down the server correctly switch it off pull out the power plug and open...

Страница 10: ......

Страница 11: ... to risks electric shock energy hazards fire hazards and could also damage the equipment Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability Before operating the device V CAUTION During installation and before operating the device observe the instructions on environmental conditions for your device If the device ...

Страница 12: ...g unit is still running but the peripheral device e g storage subsystem has failed during a power outage Data cables must be adequately shielded To the LAN wiring the requirements apply in accordance with the standards EN 50173 and EN 50174 1 2 As minimum requirement the use of a protected LAN line of category 5 for 10 100 MBps Ethernet and or of category 5e for Gigabit Ethernet is considered The ...

Страница 13: ...s that satisfy the requirements and rules governing safety and electromagnetic compatibility and relating to telecommunications terminal equipment If you install other expan sions you may damage the system or violate the safety regulations and regulations governing RFI suppression Information on which system expansions are suitable can be obtained from the customer service centre or your sales out...

Страница 14: ...and injuries Therefore check each CD DVD for damage cracks breakage etc before inserting it in the drive Please note that any additional labels applied may change the mechanical properties of a CD DVD and cause imbalance Damaged and imbalanced CDs DVDs can break at high drive speeds data loss Under certain conditions sharp edged pieces of broken CDs DVDs can penetrate the cover of the drive damage...

Страница 15: ...SD are marked with the following label Figure 1 ESD label When you handle components fitted with ESDs you must observe the following points under all circumstances Remove the power plug from the power socket before inserting or removing components containing ESDs You must always discharge yourself of static charges e g by touching a grounded object before working The equipment and tools you use mu...

Страница 16: ... Econel200 S2 Safety notes Place all components on a static safe base I You will find a detailed description for handling ESD components in the relevant European or international standards EN 61340 5 1 ANSI ESD S20 20 ...

Страница 17: ...rver correctly Ê If your operating system has not switched off the server press the ON OFF button Ê Remove the power plug from the grounded insulated socket Ê If required remove the lock on the side cover Figure 2 Removing the side cover Ê Open the latch 1 The opening of the latch pushes back the side cover 2 and disengages the hooks on the top of the side cover Ê Remove the side cover 3 1 2 3 ...

Страница 18: ...of additional memory modules or installation of a second processor the processor fan 2 has to be removed Ê Remove the side cover as described in section Opening the server on page 17 Figure 3 Removing the processor fan 2 cable Ê Disconnect the plug of the processor fan cable from the system board connector Fan2 CPU see circle ...

Страница 19: ...ight side and remove the air duct with the integrated processor fan 2 4 3 Removing the system fan For the installation of PCI controllers or installation of a second processor the system fan has to be removed Ê Remove the side cover as described in section Opening the server on page 17 Ê Remove the processor fan 2 as described in section Removing the processor fan 2 on page 18 grip ...

Страница 20: ...20 Options Guide Econel200 S2 Removing the system fan Preparation Figure 5 Removing the system fan Ê Pull the locking bar see arrow upward and remove the system fan ...

Страница 21: ...ng the memory air duct For the installation of additional memory modules or installation of a second processor the traverse with the memory air duct has to be removed Ê Remove the side cover as described in section Opening the server on page 17 Ê Remove the processor fan 2 as described in section Removing the processor fan 2 on page 18 Ê Remove the system fan as described in section Removing the s...

Страница 22: ...side see circles Ê Take out the traverse with the memory air duct carefully 4 5 Removing the processor fan 1 For the installation of additional memory modules the processor fan 1 has to be removed Ê Remove the side cover as described in section Opening the server on page 17 Ê Remove the processor fan 2 as described in section Removing the processor fan 2 on page 18 Ê Remove the system fan as descr...

Страница 23: ...he memory air duct on page 21 Figure 8 Removing the processor fan 1 Ê Disconnect the plug of the processor fan cable from the system board see circle connector Fan1 CPU Ê Pull the lock bar 1 in direction of the front side Ê Pull the system fan somewhat forward to disengage its hooks at the rear side of the server 2 and take out the processor fan 1 1 2 ...

Страница 24: ......

Страница 25: ...graded with a second processor The upgrade kit includes a processor and a heat sink V CAUTION You may only use processors of the same type on the system board The second processor must have the same type and clock rate as the first Use a suitable multiprocessor operating system if dual operation is required Ê Remove the side cover as described in section Opening the server on page 17 Ê Remove the ...

Страница 26: ... it upward until it stops 1 Ê Open the cover 2 Ê Remove the plastic cover 3 Figure 10 Inserting the processor Ê Position the new processor over the socket and press it carefully into the socket 1 V CAUTION The processor can only be installed in one particular direction Pay attention to the location mark on one of the corners Do not use force to press it into the socket to avoid damaging the pins o...

Страница 27: ...lace the heat sink onto the processor socket 1 Ê Fasten the heat sink by tightening the four screws in a crossover pattern 2 V CAUTION Never operate a processor without heat sink or without processor fan as otherwise the processor may overheat and fail causing the complete system board to fail Ê Install the traverse with the memory air duct as described in section Installing the memory air duct on...

Страница 28: ...second processor Processors Ê Install the processor fan 2 as described in section Installing the processor fan 2 on page 52 Ê Close the server connect it to the mains and switch it on as described in section Closing the server on page 53 et seq ...

Страница 29: ... Buffered DIMM memory modules The basic unit includes the first memory bank populated either with 1x 512 Mbyte 2x 512 Mbyte 2x 1 Gbyte or 2x 2 Gbyte ECC with memory scrubbing and with Single Device Data Correction SDDC Chipkill function is supported 6 1 Slot population rules Figure 12 Structure of the main memory in memory banks and memory modules The modules capacity can be different for the diff...

Страница 30: ...in section Removing the processor fan 2 on page 18 Ê Remove the system fan as described in section Removing the system fan on page 19 Ê Remove the traverse with the memory air duct as described in section Removing the memory air duct on page 21 Ê Remove the processor fan 1 as described in section Removing the processor fan 1 on page 22 Ê Unpack the memory module DIMM 1A white socket DIMM 2A black ...

Страница 31: ...rse with the memory air duct as described in section Installing the memory air duct on page 50 Ê Install the system fan as described in section Installing the system fan on page 51 Ê Install the processor fan 1 as described in section Installing the processor fan 1 on page 49 Ê Install the processor fan 2 as described in section Installing the processor fan 2 on page 52 Ê Close the server connect ...

Страница 32: ......

Страница 33: ... be installed 7 1 Installing an accessible drive I Only one USB tape drive is allowed in the server The USB tape drive can be connected directly to the onboard USB controller I Only one SCSI tape drive is allowed in the server In this case you need also a SCSI controller because there is no onboard SCSI controller on the system board Ê Remove the side cover as described in section Opening the serv...

Страница 34: ...ply with applicable EMC regulations regulations on electromagnetic compatibility and to protect against fire Ê Unpack the new drive and make the desired settings You should read the accompanying documentation supplied with the drive beforehand Ê Push the accessible drive into the free bay Ê Fasten the accessible drive with two screws Ê Connect the data cable to the accessible drive see the cabling...

Страница 35: ...ing the server on page 53 et seq 7 2 Installing the 5 inch multibay Ê Remove the side cover as described in section Opening the server on page 17 Ê Remove the processor fan 2 as described in section Removing the processor fan 2 on page 18 Ê Remove the system fan as described in section Removing the system fan on page 19 Figure 15 Screws of the lowest bay Ê Remove the two screws of the lowest bay a...

Страница 36: ... drive is removed again and not replaced with a new drive the dummy module must be reinstalled due to cooling to comply with applicable EMC regulations regulations on electromagnetic compatibility and to protect against fire Ê Unpack the 5 inch multibay Figure 16 Folding the floppy cable Ê Fold the floppy cable as shown in the photo ...

Страница 37: ...he cable clamp opened Ê Thread the floppy cable and the power cable plugs P9 P12 through the lowest bay and the front panel I The DVD ROM CD RW DVD or DVD RW drive must be removed or replaced by another drive e g USB drive before installing the slimline drive CD RW DVD DVD RW Ê Replace remove the DVD ROM CD RW DVD or DVD RW drive Ê Thread the CDROM cable connected before to the DVD ROM CD RW DVD o...

Страница 38: ...ch point and push the dummy module out of the 5 inch multibay V CAUTION Keep the dummy module for future use If the drive is removed again and not replaced with a new drive the dummy module must be reinstalled due to cooling to comply with applicable EMC regulations regulations on electromagnetic compatibility and to protect against fire ...

Страница 39: ...ure use If the drive is removed again and not replaced with a new drive the dummy must be reinstalled due to cooling to comply with applicable EMC regulations regulations on electromag netic compatibility and to protect against fire Figure 20 Inserting the slimline drive Ê Insert the slimline drive in the frame The four pins will fasten the frame Ê Slide the slimline drive into the mounting locati...

Страница 40: ...bay Lead the cables carefully into the interior of the chassis Avoid deadlocks or damage of the cables Ê Fasten the 5 inch multibay with two screws Ê Straighten the floppy and the CDROM cable and close the cable clamp Ê Install the system fan as described in section Installing the system fan on page 51 Ê Install the processor fan 2 as described in section Installing the processor fan 2 on page 52 ...

Страница 41: ... 8 1 Installing SATA hard disk drives Ê Remove the side cover as described in section Opening the server on page 17 You find the necessary pre mounted EasyClick rails in the drive cage Ê Remove the EasyClick rails from the next free bay of the hard disk drive cage installation sequence from above downward Ê Unpack the new drive and make the desired settings You should read the accompanying documen...

Страница 42: ...22 Attaching the rails to the SATA hard disk drive Ê Press the EasyClick rails upper pin row into the mounting holes of the SATA hard disk drive as shown in the figure Screws are not necessary the pins at the rails engage into the mounting holes of the drive Anschlussseite interface side ...

Страница 43: ...lug P18 from the first SATA hard disk and connect the plug to the second SATA hard disk Connect plug P17 to the first SATA hard disk SATA cable Connect the SATA cable to the system board and the SATA hard disk Cable SATA hard disk 1 belongs to system board connector SATA1 SATA hard disk2 to connector SATA2 SATA hard disk3 to connector SATA3 SATA hard disk4 to connector SATA4 position of the connec...

Страница 44: ......

Страница 45: ...Figure 24 Numbering of the PCI slots You will find further information in the Technical Manual for the system board D2530 PDF file available on the ServerBooks DVD 9 1 Installing an expansion board Ê Remove the side cover as described in section Opening the server on page 17 Ê Remove the system fan as described in section Removing the system fan on page 19 slot 6 slot 5 slot 4 slot 3 slot 2 PCI X ...

Страница 46: ...xpansion board Expansion boards in PCI slots Figure 25 Opening the locking clamp Ê Press on the two green locking levers in the direction of the arrow 1 and tilt the locking levers out of the chassis 2 Then open the slot locking bar 3 1 1 2 2 3 3 ...

Страница 47: ... a new one the slot cover has to be reinstalled to comply with applicable EMC regulations and satisfy cooling requirements and fire protection measures Ê Unpack the new expansion board and make the desired settings You should read the accompanying documentation supplied with the expansion board beforehand Ê Install the expansion board into the PCI slot and press it carefully into the associated pl...

Страница 48: ...ribed in section Installing the system fan on page 51 Ê Close the server connect it to the mains and switch it on as described in section Closing the server on page 53 et seq I Please check the relevant PCI slot settings in the BIOS manual If necessary change the settings Please read the documentation for the installed expansion board Pay attention to the allocation of the PCI interrupts You will ...

Страница 49: ...essor fan 1 Figure 27 Installing processor fan 1 Ê Put the hooks of the processor fan 1 into the recesses on the server s rear side see circles Ê Push the processor fan 1 in direction to the connector panel until the lock bar engages Ê Connect the plug of the processor fan cable to the system board connector Fan1 CPU see also figure 8 on page 23 ...

Страница 50: ... Installing the memory air duct Figure 28 Installing the traverse with the memory air duct Ê Insert carefully the traverse with the memory air duct Ê Hook the traverse at the left side see circles Ê Press on the traverse at the right side see arrow until the locking bar engages ...

Страница 51: ...Installing the system fan Figure 29 Installing the system fan Ê Hook the system fan into the traverse see circles and press it in the chassis until it clicks into place Ê Connect the system fan cable to the connector Rear fan on the system board see also figure 6 on page 21 ...

Страница 52: ...r fan 2 Ê Connect the processor fan cable to the connector Fan2 CPU on the system board see also figure 3 on page 18 Figure 30 Installing the processor fan 2 Ê Insert carefully the air duct with the integrated processor fan 2 You will find four guiding bolts on the traverse and the chassis see circles ...

Страница 53: ...Econel200 S2 Options Guide 53 Completion Closing the server 10 5 Closing the server Figure 31 Side cover recesses Ê Place the side cover into the four recesses of the chassis see circles ...

Страница 54: ... onto the chassis and close the latch The closing of the latch pushes forward the side cover and engages the hooks on the top of the side cover Ê Return the server to its original installation location Ê Reconnect any disconnected cables Ê Connect the power plug to the grounded power outlet and press the ON OFF button ...

Страница 55: ...Econel200 S2 Options Guide 55 11 Appendix 11 1 Cabling ...

Страница 56: ...ot 5 DVD ROM DVD RW CD RW DVD 0 5 optional 3 5 FDD drive optional USB3 4 USB3 4 Front panel Intr Panel 1 IDE Floppy Intr SATA4 SATA3 USB5 6 SATA5 SATA2 SATA1 SATA6 Hard disk 1 Hard disk 2 Hard disk 3 Hard disk 4 Power Supply CPU 1 P6 P7 P8 P9 P12 Y3894 V22 A3C40082391 Y3848 V101 A3C40060863 Y3922 Z11 A3C40082393 Y3662 V509 A3C40082328 Y1248 V201 A3C40062756 Chassis ID I C Y3718 V701 A3C40060864 Fa...

Страница 57: ... DVD ROM DVD RW CD RW DVD 0 5 optional 3 5 FDD drive optional USB3 4 USB3 4 Front panel Intr Panel 1 IDE Floppy Intr SATA4 SATA3 USB5 6 SATA5 SATA2 SATA1 SATA6 Hard disk 1 Hard disk 2 Hard disk 3 Hard disk 4 Power Supply CPU 1 P6 P7 P8 P9 P12 Chassis ID I C Fan 1 CPU Rear Fan Fan 2 CPU REAR FAN Y3928 V902 Y3928 V902 Y3928 V902 Y3928 V902 A3C40082479 P2 P5 P19 not used P11 not used P10 not used P20...

Страница 58: ...lot 3 Slot 4 Slot 6 FAN 1 CPU FAN 2 CPU Slot 5 USB tape drive optional CD RW DVD 0 5 optional 3 5 FDD drive optional USB3 4 USB3 4 Front panel Intr Panel 1 IDE Floppy Intr SATA4 SATA3 USB5 6 SATA5 SATA2 SATA1 SATA6 Hard disk 1 Hard disk 2 Hard disk 3 Hard disk 4 Power Supply CPU 1 Chassis ID I C Fan 1 CPU Rear Fan Fan 2 CPU REAR FAN SCSI Contr Y3980 V11 A3C40080765 use the delivered cable ...

Страница 59: ...e on the Internet can be found via the URL http manuals fujitsu siemens com For the documentation of the PRIMERGY servers choose the navigation point industry standard servers 1 Safety notes and other important information 2 Warranty 3 Ergonomics 4 Returning used devices 5 Econel 200 S2 Server Operating Manual 6 System Board D2530 Technical Manual 7 D2530 Setup Utility Reference Manual 8 Quick Sta...

Страница 60: ...nt User Manual 13 PRIMERGY ServerView Suite ServerView Server management User Manual 14 PRIMERGY ServerView Suite RemoteView User Manual 15 ServerView RAID User Manual 16 LSI SATA Software RAID User Manual 17 Global Array Manager Client Software User s Guide 18 Global Array Manager Server Software User s Guide ...

Страница 61: ... boards 7 H hard disk drives 41 heat sink 27 I information 6 L light emitting diode LED 15 lithium battery 14 M main memory 7 29 meaning of the symbols 8 memory air duct 21 50 multiprocessor operating system 25 N notational conventions 8 note about the laser 15 P PCI slots 45 processor 7 25 heat sink 27 processor fan 1 22 49 processor fan 2 18 52 S SATA hard disk drive 7 server closing 53 opening ...

Страница 62: ......

Страница 63: ...00 S2 Server Econel200 S2 Comments Suggestions Corrections Submitted by Fujitsu Siemens Computers GmbH User Documentation 81730 Munich Germany Fax 49 700 372 00000 e mail manuals fujitsu siemens com http manuals fujitsu siemens com ...

Страница 64: ......

Страница 65: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen Diese neue Tochtergesellschaft von Fujitsu trägt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nic...

Отзывы: